Laserfiche WebLink
-,;)► Continuous Line Ie#Monitoring - <br /> Automatic Ale Repress urization <br /> The ISM-4080 and ISM-4081 automatically monitor Vmi mechanical line leak detectors. After an authorization <br /> is received, the leak detector must open before dispensing begins or the submersible is shut down. Between <br /> dispensing cycles, the ISM continuously monitors the line pressure.A line test/auto repressurization sequence is <br /> initiated every time line pressure falls below 12 PSI. The test (when passed) additionally recharges the delivery <br /> system, combating thermal contraction, keeping the line pressurized and ready for fuel delivery. Long pipe runs <br /> and flexible pipe systems are automatically compensated for, while preventing false alarms. <br /> No New Wires to the Submersible Pump Sump Containment <br /> The ISM-4080 and ISM-4081 modules monitor the Leak Detector Sensor(piston switch).The Leak Detector Sensor <br /> Housing is screwed into the Vmf 99 Series-99 LD-2000 or 99 LD-3000 mechanical line leak detector vent opening. <br /> An alternative vent is provided in the sensor housing. Only a single pair of wires is needed to monitor and discriminate <br /> between the Leak Detector Sensor and an (optional) single point, normally closed, intrinsically safe sump sensor. <br /> If a sump sensor has been previously installed in the sump, no new wire need be pulled for the installation of the <br /> ISM-4080. On new installations, separate wiring may be installed for both the sump sensor and the Leak Detector <br /> Sensor. With separate wiring to the sump sensor and the Leak Detector Sensor,the ISM-4081 may be programmed <br /> to actuate an alarm only or provide shutdown of the submersible during sump sensor activation. <br /> qA Manifolded Submersible Control <br /> Multiple submersibles into one line, all starting at the same time, overcome catastrophic line leak detection <br /> function. The installation of an ISM module (and piston sensor) allow multiple submersibles feeding into a single <br /> delivery line to be wired in such a manner to enable hourly catastrophic (3 GPH @ 10 PSI) testing. This is an <br /> inexpensive fix to a common problem. <br /> Line Leak Monitoring Reports Through Automatic Site Monitoring <br /> Equipment Auxiliary Sensor Inputs <br /> Low Pressure Alarms and Sump Alarms (optional) are detected and displayed on the ISM Module.Alarm reports <br /> may be monitored through the ISM only, or connected in parallel to a Site Monitoring System to provide for the <br /> remote reporting of alarms.Additionally,the alarm output contacts may be used with stand-alone audible or visual <br /> devices. Wiring diagrams are provided in the ISM Installation and Operation Manual. <br /> No Interference with Automatic Tank Testing <br /> If tank monitoring (testing) equipment needs specific "quiet" times to perform testing, the ISM will provide <br /> uninterrupted test time, based upon time of day (programming set-up)or based on an AC or DC input signal from <br /> the site tank test equipment. <br /> Works with Vml "99" Series Mechanical Line Leak Detectors <br /> To allow ISM monitoring of the 99 LD-2000 Line Leak Detector,the ISM-4101 Le k D r Sensor/Housing <br /> is uired for retrofit and new installations. To allow ISM monitoring of the 99 LD-3000 Line Leak Detector, <br /> the ISM-4102 eak Detector Sensorl Housing is required for retrofit and new installations. <br /> 4 1/8' <br /> 1­(105mm)� <br /> z� <br /> Z' mm <br /> L <br /> Q OUR i� <br /> T.a 6 3/8" <br /> DISPLAY 3 1/2' (162 mm) <br /> (89mm) <br /> OD y RSTO <br /> we ZZ0000 <br /> ie <br /> DIN RAIL RELEASE <br /> 4' <br /> (101 mm) <br /> 2 114' <br /> ODDODD ❑O 00 ❑ODDOD (57mm) <br />