My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
4800
>
2300 - Underground Storage Tank Program
>
PR0231509
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 4:04:57 PM
Creation date
11/2/2018 8:31:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0231509
PE
2361
FACILITY_ID
FA0003809
FACILITY_NAME
A G SPANOS AVIATION DEPT*
STREET_NUMBER
4800
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
4800 S AIRPORT WAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\4800\PR0231509\COMPLIANCE INFO 2008 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2008 - 2015
QuestysRecordDate
9/14/2017 6:56:06 PM
QuestysRecordID
3636962
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
265
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> =-Underground <br /> East Hazelton Avenue, Stockton, California 95205-6232 <br /> (209)468-3420 Fax:(209)468-3433 Web:www sjoov ora/ehd <br /> Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: ElFebruary <br /> ate: <br /> A G SPANOS AVIATION DEPT* (209) 982-1550 27, 201 <br /> Facility Address: <br /> 4800 S AIRPORT WAY, STOCKTON, CA 95206 EPA Io- ERS ID:0181439 <br /> Facility Contact: Contact Phone: Contact during <br /> A G SPANOS CONSTRUCTION C Einspection., if(209) 982-1550 different fromct:Inspection type: Program:ROUTINE INSPECTION -Operating Permit 2361 - UST FACILI <br /> CCR=California Cade of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> V2632 <br /> 284 No permit to operate <br /> ❑V ❑R ❑COS <br /> 84(a)(3) No written agreement between tank owner and tank operator to monitor the tank system ❑V ❑R ❑COS <br /> 92.2 Current financial responsibility documents not submitted <br /> ❑V ❑R ❑COS <br /> 11 UST Operating Permit Application for Facility and Tank information not submitted or cement <br /> ❑V ❑R ❑COS <br /> 86(C) Current BOE number not submitted <br /> ❑V ❑R ❑COS <br /> 2 Monitoring and response plans not current or approved by the EHD <br /> ■V o ❑COS <br /> dO7CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ❑V ❑R ❑COS <br /> CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testingnV ❑R ❑COS <br /> CCR 2637 Failed to test secondary containment <br /> ❑V ❑R ❑COS <br /> CCR 2637(e) Failed to submit secondary containment test report within 30 days ❑V ❑R ❑COS <br /> CCR 2638(a) Failed to test monitoring and leak detection equipment annually <br /> ❑V oR ❑COS <br /> 112 HSC 25284.2 Failed to test spill containers annually <br /> ❑V ❑R ❑COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days <br /> ❑V ❑R ❑COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br /> ❑V ❑R ❑COS <br /> 115 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days ❑V ❑R ❑COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC centifi cation ❑V u R o COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1000'of a public well ❑V ❑R ❑COS <br /> 118 HSC 25292.5 Failed to repair and retest system due to failed ELD test <br /> ❑V oR ❑COS <br /> 119 CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days <br /> ❑V oft ❑COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after ❑V ❑R ❑COS <br /> 121 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V ❑R ❑COS <br /> 122 HSC 25299 Documents were falsified or misrepresented <br /> ❑V ❑R ❑COS <br /> 123 CCR 2661 Permit to repair UST system not obtained ❑V ❑R ❑COS <br /> 124 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V ❑R ❑COS <br /> 125 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report ❑V oR ❑COS <br /> 126 HSC 25404(e)(4) Failed to report program data electronically <br /> ■V ❑R ❑COS <br /> On Site Records <br /> Receiv QY(i al): Inspector:C Phone: Date: <br /> ELENA MANZO, REHS (209) 953-7699 02/27/2015 <br /> e1 Of <br />
The URL can be used to link to this page
Your browser does not support the video tag.