My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
5000
>
2300 - Underground Storage Tank Program
>
PR0503497
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 4:12:44 PM
Creation date
11/2/2018 9:05:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0503497
PE
2381
FACILITY_ID
FA0005867
FACILITY_NAME
STOCKTON METRO AIRPORT*
STREET_NUMBER
5000
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
02
SITE_LOCATION
5000 S AIRPORT WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\5000\PR0503497\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
11/29/2011 8:00:00 AM
QuestysRecordID
94633
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNLA WATER RESOURCES CONTROI BOARD <br /> FORM 'B': UNDE7RGROUND STORAGE TANK PROwAAM ;9� <br /> TANK TANK PERMIT APPLICATION INFORMATION � -°_�, <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. 10 <br /> - +1 <br /> MARK ONLY ❑ 1 NEW PERMIT 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑6 TANK REMOVED 12— ca <br /> Q S d/� A{/ FARM TANK-YES NO W <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 'l w <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY O <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: A <br /> C.YEAR INSTALLED D. TANK CAPACITY IN GALLONS: {/ <br /> II. TANK ONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑3 IESEL <br /> 3 CHEMICAL PRODUCT 4 OIL 1 PRODUCT ❑ 4 GASAHOL ❑5 JET FUEL 6 AVIATION GAS <br /> 5 HAZARDOUS 80 EMPTY ❑95 UNKNOWN 2 WASTE ❑7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED A C.A.S.# /OO o C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,A D <br /> A TYPE OF ❑ 1 POUBLE WALLED ❑ 3 SINGLE WALLED WITH B(TERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT 99 OTHER <br /> ❑ 1 BTEEUIRON ❑2 STAINLESS STEEL 3 FIBERGLASS ❑ 4 STEEL CLAD WYRBERGLASS REINFORCED PLASTIC <br /> B.TANK F-1 5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 UMINUM F-1 610096 METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> 9 BRONZE 10 GALVANIZED STEEL UNKNOWN ❑99 OTHER <br /> ❑ 1 RUBBER LINED ❑2 ALKYD LINING ❑3 EPDXY UNING OLICUNING <br /> C.INTERIOR ❑ <br /> LINING 5 GLASSUNING F-16 UNLINED 95 UNKNOWN <br /> ❑ ISUNING MATERIAL COMPATIBLE WITH 10096 METHANOL? YES ❑ NO ❑ 99 OTHER <br /> D. CORROSION ❑ 1 POLYETHLEME WRAP ❑2 TARONASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE ff� UNKNOWN 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE IPVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZEDSTEEL A U 5 UNKNOWN A U 99 OTHER <br /> V.LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> 'l>/ P 8 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> v 8 6 PRECISION TESTING S 7 PRESSURETESTING P 8 91 NONE P 8 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING INGALLONS INERT MATERIAL? ❑YES E] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED B SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> CURRENT LOCAL AGENCY FACILITYUp# � l AP�VEAME PHONE#WITH AREA CODE <br /> J�(/ <br /> PERMIT NUMBER PERMIT APPyRO�VAL PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT CHARGE AMT. FEE CODE Ll PTO BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A ``ENT FORMA' NAS BEEN FILED <br /> DATA PROCESSING COPY <br />