My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
741
>
2300 - Underground Storage Tank Program
>
PR0232586
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 4:14:55 PM
Creation date
11/2/2018 9:07:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232586
PE
2381
FACILITY_ID
FA0003507
FACILITY_NAME
ACCENT PAPER WAREHOUSE
STREET_NUMBER
741
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15131008
CURRENT_STATUS
02
SITE_LOCATION
741 S AIRPORT WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\741\PR0232586\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
11/22/2011 8:00:00 AM
QuestysRecordID
95816
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CAUFORMA <i <br /> STATE WATER RESOURCES CONTROL BOARD '>, <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION• FORM B `.� <br /> COMPLETE.A SEPARATE FORM FOR EACH TANK SYSTEM. I <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION a 7 PERMANENTLY CLOSED ON SITE <br /> ONE REM ❑ 2 INTERIM PERMIT O 4 AMENDED PERMIT /❑ 6 TEMPORARY TANK CLOSURE EDB TANK REMOVED O <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: — 5 A]r c�✓"7 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNERS TANK I.D.a O B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) �� D. TANK CAPACITY IN GALLONS: <br /> ILTANK C NTS IF A-1 IS MARKED,COMPLETE REM C. <br /> A, 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. ❑ IAUNLEADDERD DIESEL ❑ 6 AVIATIONGAS <br /> ❑ 2 PETROLEUM ❑ N EMPTYO PRODUCT 1PPREMIUM 4 IS L 7 METHANOL <br /> ❑ UNLEADED 6 JET FUEL ❑ <br /> ❑ 3 CHEMICAL PRODUCT ❑ 05 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A.S.s <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C,AND ALL THAT APPLIES IN BOX D AND <br /> A TYPE OF ❑ 1 USLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM GLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> S. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 6 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 6 IW% METHANOL COMPATIBLE WTRP <br /> (PrimaryTank) ❑ 0 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 NYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C I TENOR ❑ 5 GLASS LINING 6 UNLINED ❑ 95 UNKNOWN 09 OTHER <br /> LIN <br /> IS LINING MATERIAL COMPATIBLE WITH 10D% METHANOL? YES_ NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ATING ❑ 3 VINYL WRAP ED4 FIBERGLASS REINFORCED"PLASTIO <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELW/COATING <br /> A U S 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ MCNrron.G ❑W OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ N OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST U D(MO/DAY/YR) 2.ESTIMATED QUANTITY OF ^ 3.WAS TANK FILLED WITH YES NO <br /> 9Z. SUB STAN CE REMAINING (/ GALLONS INERT MATERIAL? ❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> IPPoNTED 8 SIGNATUREI <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY 9 JURISDICTION# FACILITY a TANK A {'}CC EAU T/ <br /> STATE LD.# ma 8 � I I I IO I <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT E)(P,IRATION ATE( } <br /> FORM B (7 911 THIS FORM MUST BE ACCOMPANIED BY APERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> _/,1� FORo6w <br />