My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
7611
>
2300 - Underground Storage Tank Program
>
PR0231511
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2022 2:36:20 PM
Creation date
11/2/2018 9:07:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231511
PE
2361
FACILITY_ID
FA0003695
FACILITY_NAME
ESTES TRUCKING
STREET_NUMBER
7611
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17705029
CURRENT_STATUS
01
SITE_LOCATION
7611 S AIRPORT WAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\7611\PR0231511\BILLING 2013 - 2015.PDF
QuestysFileName
BILLING 2013 - 2015
QuestysRecordDate
1/23/2018 5:52:37 PM
QuestysRecordID
3769220
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NIFIED PROGRAM CONSOLIDATED FORD TANK: TA0508223 <br /> N.W, &jr <br /> PR#: PR0231511 <br /> UNDERGROUND STORAGE TANKS -TAN FAC#: FA0003695 <br /> a O (two pages per tank) <br /> Page 3 00 <br /> TYPE OF ACTION <br /> ❑ I NEW SITE PERMIT ❑4 AMENDED PERMIT ❑ 3 CHANGE OF INFORMATION b TEMPORARY SRE CLOSURE <br /> (CI}mtyitam wdy) ®® ®® <br /> PERMANENTLY CLOSED ON SITE <br /> ❑ 3RENEWAL PERMIT ❑STANK REMOVED uo <br /> BUSINESS NAME(Sure.FACB.DYNAME orDRA-Doing thaw.Ac) FACILITY ID: PR#: l <br /> 3 FA0003695 PR0231511 <br /> LOCATION WITHIN SITE(IlpgwW) 7611 S AIRPORT WAY,STOCKTON 431 <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landnvrks shall be suMmtted to the local agency.) <br /> TANK ID# Tank#: 2 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Y,,s ❑No 434 <br /> TA0508223 I XERXE$ B"Ym',caryks mewse rare„6 w,m.m�e <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 11/5/1998 12,000 <br /> ADDITIONAL DESCRIPTION(Fort-1 me amy) 438 <br /> D.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® I.MOTOR VEWCLEFUEL ❑ Ia.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (IrmrkWm .Pm -Type) ❑ lb.PREMIUM UNLEADED ® 3.DIESEL ❑ b.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ is MIDGRADE UNLEADED ❑ 4.GASOHOL ❑ 99.OTHER <br /> ❑3.CHEMICAL PRODUCT COMMON NAME(6om H�&Ud i sIrvmn page) 441 CAS#(6am Havrame Materia6 hrvm[my page) 412 <br /> ❑4.HAZARDOUS WASTE <br /> mmluda Uaed an <br /> ❑ 95.UNKNOWN <br /> Ill.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SNGLE W ALL WITH ❑ S.SINGLE WALL WITH INTERNAL BLADDER SYSTEM a3 <br /> (aurk mcitsn mN) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-primary mnk ❑ LBARESTEEL M FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 441 <br /> (Chskmcimnmly) ❑ 2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99 OTHER <br /> TANK MATERIAL-secondary tank ❑ I.BARESTEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN MS <br /> (Chak=nmordy) ❑2.STAINLESS STEEL ❑4.STEELCLADW/FIBERGLASS ❑ 8.FRPCOMPTIBLEW/100%METHANOL <br /> UNFORCED PLASTIC(FRP) ❑ H.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ I.RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS FIXING E]95.UNKNOWN 446 DATE INSTALLED at <br /> OR COATING <br /> (CMk arc im only) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ® 6 UNLINED ❑ 99.OTHER <br /> (Pwlod me only) <br /> OTHER CORROSION ❑ 1 MANUFACTURING CATHODIC ® 3 FIBERGLASS UNFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED a9 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Chakancimn Myl ❑ 4 IMPRESSED CURRENT El 990THER <br /> [:] 25ACRIPICIAL ANODE (Fsbd ue mly) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(loml we mb) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> ❑ 1 SPILL CONTAINMENT 1,998.00 ❑ 1 ALARM ❑ 3 PILL TUBE SHUT OFF VALI <br /> ❑ 2 DROP TUBE ❑ 2 BALL ❑ 4 EXEMPT <br /> ❑ 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A de.oiptlm orwn n skt gpsa 3m 11 he ssbmsn,dto the 1pol ag y.) <br /> IF SINGLE WALL TANK(Check.H dumpy) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ i VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Clw&a nmi my) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE <br /> ❑ i VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑3 CONTINUOUS ATG ❑ J GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SBR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 451 <br /> 11/5/1998 0.00 gallons ❑Yna ❑ No <br /> UPCF(12/99 revised) <br />