D. Results of Testing/Servicing <br />Software Version Installed: 16.05 <br />Cmmnlafa tha fnllnw rhn,411c1. <br />MAY 2 7 201.5 <br />f <br />® Yes <br />❑ No' <br />Is the audible alarm operational? <br />® Yes <br />❑ No' <br />Is the visual alarm operational? <br />® Yes <br />❑ No' <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />❑ Yes <br />® No' <br />Were all sensors installed al lowest point of secondary containment and positioned so that other equipment will not inh their properoperation? <br />❑ Yes <br />❑ No' <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) operational? <br />® N/A® <br />Yes <br />❑ No' <br />For pressurized piping systemsdoes the turbine automatically shut down if the piping secondary containment monitorinetects a leak,❑ <br />N/A <br />fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut -down? (Check all that aSump frenchSensors; ❑ Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ® Yes; ❑ No. <br />jhh <br />❑ Yes <br />❑ No' <br />For tank systems that utilize the monitonng system as the primary tank overfill warning device (i.e., no mechanical ovntion valve isN/A <br />installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what tank capacitydoes <br />the alar trigger? % <br />❑ Yes <br />® No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list acturer name <br />and model for all replacement parts in Section E, below. <br />[]Yes* <br />® No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product; ❑ Water. If yes, describe causes in Section E, below. <br />® Yes <br />❑ No' <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, If applicable <br />® Yes❑ <br />No' I <br />Is all monitoring equipment operational per manufacturer's specifications? <br />In Section E below, describe how and when these deficiencies were or will be contacted. <br />SENSOR IN STP SUMP LAYING ON MANWAY IN SUMP. SITE SPECIFIED DURING <br />MONTHLY CLEANING THEY MOVED AND DID NOT KNOW WHERE TO PUT IT. <br />E. Comments: LEFT IT FOR ME TO PUT IN CORRECT POSITION, CORRECTLY PLACED. <br />Monitoring System Certification Page 2 of 4 2/21/07 <br />