Adbk a aarâ– aiwrra <br />San ,Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />77611 <br />Facility Address: <br />Date: <br />ESTES TRUCKING <br />S AIRPORT WAY STOCKTON <br />May 20 2016 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item ## <br />Remarks <br />104 <br />CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br />UST Tank Information form for the diesel tank is not current in CERS. The tank primary containment was listed as <br />steel. This should be listed as fiberglass. The piping sump was listed as double wall. This should be listed as single <br />wall. The vent piping transition sump was listed as double wall. This should be listed as none. The vent piping <br />secondary was listed as fiberglass. This should be listed as none. The vapor piping primary and secondary were listed <br />as fiberglass. These should be listed as none. The fill riser secondary was listed as fiberglass. This should be listed <br />as none. The fill sump was listed as yes. This should be listed as no. Any change of information must be updated in <br />CERS within 30 days of the changes. During the inspection, the employee made corrections to the CERS submittal <br />and uploaded it. Continue to log into CERS, update the required information, and submit for review by the EHD as <br />needed. <br />This was corrected on site. <br />This is a Class II violation. <br />106 <br />CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />The monitoring plan is not current and not approved by the EHD. The pipe monitoring leak sensor model number was <br />listed as 205. This should be listed as 208. The monitoring plan must be uploaded to the California Environmental <br />Reporting System (CERS). During the inspection the employee updated the monitoring plan in CERS. Continue to log <br />into CERS, make the necessary changes, and submit for review by the EHD as needed. <br />This was corrected on site. <br />This is a repeat violation, Class H. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. A legend key was not included to identify what the <br />symbols represented on the site map. The site map did not indicate that a leak detector was present. A site plan <br />must be submitted identifying the locations where monitoring will be performed. During the inspection, the employee <br />updated the site map and uploaded it in California Environmental Reporting System (CERS). Continue to log into the <br />CERS at http:llcers.calepa.ca.gov/ and upload a current copy of the UST Monitoring Site Plan as needed. <br />This was corrected on site. <br />This is a minor violation. <br />Page 4 of 7 <br />