Laserfiche WebLink
ci 4. <br />GFTTIFR-NYAN IN(. GR Job # 20-631623""U <br />Appendix VI JUL 15 2015 <br />MONITORING SYSTEM CERTIFICATION -Nw iR0!`\1 FNTA' <br />For Use By All Jurisdictions Within the State of Califomia --a <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />ownerloperator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. Generallnformabon <br />Facility Name: Estes Express Bldg. No.. <br />Site Address: 7611 S Airport Way City: Stockton zip: <br />Facility Contact Person Contact Phone No.. <br />Make/Model of Monitoring System: TLS -350 Date of TestinglServicing: 7/1/2015 <br />B. Inventory of Equipment TestedlCertified <br />Check the appropriate boxes to Indicate <br />Tank ID: Diesel <br />M <br />In -Tank Gauging Probe. <br />0 <br />Annular Space or Vault Sensor. <br />M <br />Piping Sump 1 Trench Sensor(s). <br />❑ <br />Fill Sump Sensor(s). <br />❑ <br />Mechanical Line Leak Detector. <br />❑ <br />Electronic Line Leak Detector <br />❑ <br />Tank Overfill! Nigh -Level Sensor. <br />❑ <br />Other (specify equipment type and r <br />Tank <br />ID: <br />❑ <br />In -Tank Gauging Probe. <br />❑ <br />Annular Space or Vault Sensor. <br />❑ <br />Piping Sump! Trench Sensor(s). <br />❑ <br />Fill Sump Sensor(s). <br />❑ <br />Mechanical Line Leak Detector <br />❑ <br />Electronic Line Leak Detector <br />❑ <br />Tank Overfill I High -Level Sensor. <br />❑ <br />Other (specify equipment and n <br />Dispenser ID: <br />❑ <br />Dispenser Containment Sensor(s) <br />E3 <br />Shear VaNe(s). <br />❑ <br />Dispenser Containment Fli and <br />Dispenser ii <br />❑ <br />Dispenser Containment Sensor(s). <br />❑ <br />Shear Valve(s). <br />❑ <br />Disoenser Containment Flnaflcl anri <br />Dispenser [D: <br />Model: MAG t <br />Model: 744380.303 <br />Model: 794380-206 <br />Model: <br />Model: <br />Model: <br />Modei <br />in Section E on Pane 9) <br />Model: <br />Model <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />in Section E on Pane 21 <br />Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Shear Valve(s)- <br />❑ Dispenser Containment Floats and Chains . <br />If the facility contains more tanks or dispensers, copy this form <br />I Tank ID: <br />❑ <br />In -Tank Gauging Probe <br />❑ <br />Annular Space or Vault Sensor. <br />❑ <br />Piping Sump I Trench Sensor(s). <br />❑ <br />Fill Sump Sensor(s). <br />❑ <br />Mechanical Line Leak Detector. <br />❑ <br />Electronic Line Leak Detector <br />❑ <br />Tank Overfill/ High -Level Sensor. <br />❑ <br />Other (specify equipment type anc <br />Tank <br />ID: <br />❑ <br />In -Tank Gauging Probe. <br />❑ <br />Annular Space or Vault Sensor. <br />❑ <br />Piping Sump I Trench Sensor(s). <br />❑ <br />Fill Sump Sensor(s). <br />❑ <br />Mechanical Line Leak Detector. <br />❑ <br />Electronic Line Leak Detector <br />❑ <br />Tank Overfill i High -Level Sensor. <br />❑ <br />Other specify equipment type and <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s) <br />E3 Shear Vah+e(s). <br />Dispenser 10: <br />❑ Dispenser Containment Sensor(s) <br />❑ Shear Valve(s), <br />❑ n;-—, _. <br />Dispenser Ii <br />❑ Dispenser Containment Sensor(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Floalrst ani <br />for every tank and dispenser at the facility. <br />Model: <br />Model_ <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />in Sect <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />model In Sect <br />Model: <br />Chains . <br />Model <br />Chain(s), <br />Model <br />e. Certification - I certify that the equipment identified in this document was Inspectedlserviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is Informatlon (e.g. manufacturers' checklists) necessary to verify that this Information Is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): .lose Carrasco Signature: r 31-v <br />Certification No B35934 <br />License. No. 220793 <br />Testing Company Name: Gettler-R an Inc. Phone No.. 925-551-7555 <br />Testing Company Address: 6805 Sierra Court Suite G, Dublin, Ca. 94568 <br />Monitoring System Certification <br />Page 1 of 4 <br />Date of Testing/Servicing: 711/2015 <br />12107 <br />