Laserfiche WebLink
Page 2of5 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s,19ov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />ESTES TRUCKING <br />Facility Address: Date: <br />7611 S AIRPORT WAY STOCKTON Ma <br />File Review <br />15 2015 <br />126 <br />HSC 25404(e)(4) <br />Failed to report program data electronically <br />oV u nCOS <br />On Site Records <br />201 <br />202 <br />203 <br />204 <br />205 <br />206 <br />207 <br />208 <br />1 CCR 2712(b) <br />CCR 2712(b) <br />CCR 2712(b) <br />CCR 2712(i) <br />CCR 2712(i) <br />HSC 25294, 25295 <br />CCR 2715 <br />CCR 2715 <br />Failed to maintain alarm logs and/or records of follow up actions <br />Failed to maintain cathodic protection test records on site for at least 6 112 years <br />Failed to maintain records of monitoring, repair, lining, and upgrades on site <br />Current monitoring plan approved by the EHD not found on site <br />Operating permit not on site <br />Failed to record or report unauthorized release in appropriate time frame <br />Designated operator did not inspect all required items and/or the inspection reports not completed <br />Designated operator monthly inspection reports not maintained on site for at least 12 months <br />a V n R ■ COS <br />o V ❑ R a COS <br />❑ V ❑ R o COS <br />❑ V n R n COS <br />n V ❑ R o COS <br />❑ V o R o COS <br />n V o R o COS <br />■ V ❑ R ■COS <br />209 <br />210 <br />211 <br />212 <br />CCR 2715(f) <br />CCR 2715(f)(2) <br />HSC 25281.5(b)(2) <br />HSC 25281.5(b)(3) <br />Designated operator employee training not performed or log not kept <br />Unstaffed facility failed to have or implement a training program approved by the EHD <br />Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />Unburied emergency generator fuel piping not visually inspected at least monthly or log kept <br />n V a R o COS <br />❑ V a R n COS <br />❑ V o R o COS <br />❑ V n R o COS <br />UST System Observations <br />301 <br />302 <br />303 <br />304 <br />305 <br />306 <br />307 <br />308 <br />309 <br />HSG 25292.1 <br />HSC 25291(b) <br />HSC 25290.2(d) <br />HSC 25290.1(d) <br />HSC 25290.1(e) <br />CCR 2630(d) <br />CCR 2632(c) <br />CCR 2636(f) <br />CCR 2636(f)(1) <br />UST system is not operated to prevent unauthorized release, including spills and overfills <br />UST system incapable of detecting leak from primary into secondary containment (pre -Jul 2003) <br />Monitoring system not maintained to detect entry into secondary containment (Jul 2003 -Jun 2004) <br />Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) <br />VPH monitoring of the interstitial spaces of the UST system is not maintained <br />Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity <br />Monitoring system of the interstitial space of a double walled system not maintained <br />Failed to maintain a continuous monitoring system that activates an audible and visual alarm <br />Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC <br />❑ V o R ❑ COS <br />Ei V o R n COS <br />❑ V ❑ R o COS <br />n V o R ❑ COS <br />❑ V o R ❑ COS <br />❑ V ❑ R ❑ COS <br />❑ V ❑ R n COS <br />❑ V ❑ R COS <br />r V ❑ R ■ COS <br />310 <br />311 <br />312 <br />313 <br />314 <br />315 <br />316 <br />317 <br />CCR 2636(f)(1) <br />CCR 2636(f)(5) <br />CCR 2636 <br />CCR 2638(f) <br />CCR 2631(a) <br />HSC 25290.2(c)(1) <br />HSC 25290.1(c)(1) <br />HSC 25290.1, 25290,2, <br />25291 <br />Sensor in a turbine sump failed to activate an audible and visual alarm or stop the flow product <br />Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs <br />Failed to property program or operate leak detection equipment <br />i Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced <br />Primary containment not tight (pre -Jul 2003) <br />Primary containment not tight (Jul 2003-Jun2004) <br />Primary containment not tight (after Jun 2004) <br />Secondary containment not tight <br />n V ❑ R c COS <br />n V ❑ R o COS <br />❑ V a R u COS <br />n V ❑ R n COS <br />❑ V o R ❑ COS <br />❑ V ❑ R Li COS <br />o V D R o COS <br />❑ V r R ❑COS <br />318 <br />CCR 26 <br />Failed to have secondary containment <br />❑ V ❑ R ❑COS <br />Received by <br />(initial): <br />Inspector. Phone: Date: <br />CINDY VO, EH Specialist (70 (209) 468-8257 4511512015 <br />Page 2of5 <br />