Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 <br /> (Two pages per tank) <br /> Page_I_of_2 <br /> TYPE OF ACTION ❑ I.NEW PERMIT ❑ 4.AMENDED PERMIT ® 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Chink one item only) ❑ 3.RENEWAL PERMIT _signaum.fowner ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (speelfi moon) (spwfy mssm) ❑ S.TANK REMOVED <br /> BUSINESS NAME(Semea.FACILITY NAME.,DBA-Wi,Bonino,As) 3. FACILITY ID: 1. <br /> GI Truckng Company dba Estes West <br /> LOCATION WITHIN SITE(Dpemm) 431. <br /> 1.TANK DESCRIPTION <br /> (A scaled Plot plan With the location of the UST astern including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432. TANK MANUFACTURER 433- COMPARTMENTALIZED TANK ❑Yes Z No 4E4. <br /> If"Yes. complete one page fm each comparlmml. <br /> DATE INSTALLED 435, TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> 1999/May 12,000 1 <br /> ADDITIONAL DESCRIPTION(Folbd use Dory) 4314 <br /> Il.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE <br /> oar. <br /> ® 1. MOTOR VEHICLE FUEL ❑Ia. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> OfcheckQ complete Petroleum Tpe) ❑Ib. PREMIUM UNLEADED ®3. DIESEL 06. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME(from Hivardote Materiels lncmton page) -1. CAS#(ham Hwmdous Materials ln.mton page) a2. <br /> ❑ 4. HAZARDOUS WASTE <br /> (Ind Wes Used Oi0 <br /> ❑ 95.UNKNOWN <br /> 111.TANK CONSTRUCTION <br /> TYPE OFTANK ❑ L SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443_ <br /> (Check one item only) MEMBRANE LINER 095. UNKNOWN <br /> ®2. DOUBLE WALL [14, SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-prinun lank ❑ 1. BARESTEEL ®3. FIBERGLASS/PLASTIC 5. CONCRETE 0 95.UNKNOWN 444. <br /> (Check me itenoih) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑S. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC FRP W/100%METHANOL <br /> TANK MATERIAL-secondary lank 0 I. BARE STEEL D9 3. FIBERGLASS/PLASTIC ❑S. FRP COMPTIBLE W/100%METHANOL 95.UNKNOWN 415. <br /> (Check one item only) ❑2. STAINLESS STEEL❑4. STEEL CLAD W/FIBERGLASS [19. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑I.RUBBER LINED 3.EPDXY LINING 0 5.GLASS LINING 0 95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> Check one tem onl <br /> OTHER CORROSION I.MANUFACTURED CATHODIC M 3.FIBERGLASS REINFORCED PLASTIC 0 95.UNKNOWN4ag. DATE INSTALLED 449, <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> (If Applicable) 2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEARINSTALLED 450. TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEARINSTALLED 452 <br /> (Check all that apply) ®L SPILL CONTAINMENT _May1999_ obwc2100 C3 1.ALARM ®3.FILLTUBE SHUT OFF VALVE <br /> ®2.DROP TUBE _May 1999_ obw61so [12.BALL FLOAT [14.EXEMPT <br /> ®3.STRIKER PLATE May 1999 steel <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑I. VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑I.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4.STATISTICAL INVENTORY RECONCILIATION ❑R.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING 099.OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455_ ESTIMATED QUANTITY OF SUBSTANCE REMAINING 4M- TANK FILLED WITH INERTMATERIAL? 457. <br /> gallons ❑Yes ❑ No <br /> UPCF hwftvrc-b(1/99)-1/4 http://w"m.unidoes.org Rim.02116/00 <br />