Laserfiche WebLink
• IN-TANK SETUP <br /> - - - - - - - - - - - - <br /> WOO <br /> T 1 :DIESEL <br /> PRODUCT CODE 1 <br /> THERMAL COEFF : .000045- <br /> TANK DIAMETER 89.75 <br /> TANK PROFILE 1 PT <br /> FULL VOL 11527 <br /> FLOAT SIZE: 4.0 IN. 6496 <br /> SYSTEM SETUPCOMMUNICATIONS SETUP <br /> - - _ - - - - - - - - - _ WATER WARNING 1 .5 <br /> MAY 17, 2010 17:20 HIGH WATER LIMIT: 2.0 <br /> PORT SETTINGS: MAX OR LABEL VOL: 11527 <br /> OVERFILL LIMIT 90% <br /> SYSTEM UNITS COMM BOARD : 1 (RS-232) 10374 <br /> U.S. BAUD RATE : 9600 HIGH PRODUCT 95% <br /> SYSTEM LANGUAGE PARITY : EVEN 10950 <br /> ENGLISH STOP BIT : 1 STOP DELIVERY LIMIT 15% <br /> SYSTEM DATE/TIME FORMAT DATA LENGTH: 7 DATA 1729 <br /> MON DD YYYY HH:MM:SS <br /> LOW PRODUCT 1000 <br /> ESTES TRUCKING AUTO TRANSMIT SETTINGS: LEAK ALARM LIMIT: 99 <br /> 7611 S.AIRPORT WY SUDDEN LOSS LIMIT: 99 <br /> STOCKTON.CA AUTO LEAK ALARM LIMIT TANK TILT 0.00 <br /> DISABLED <br /> AUTO HIGH WATER LIMIT MANIFOLDED TANKS <br /> SHIFT TIME 1 : DISABLED DISABLED T#: NONE <br /> SHIFT TIME 2 : DISABLED AUTO OVERFILL LIMIT <br /> SHIFT TIME 3 : DISABLED DISABLED <br /> SHIFT TIME 4 : DISABLED AUTO LOW PRODUCT LEAK MIN PERIODIC: 51% <br /> DISABLED 5878 <br /> TANK PERIODIC WARNINGS AUTO THEFT LIMIT <br /> DISABLED DISABLED LEAK MIN ANNUAL 51% <br /> TANK ANNUAL WARNINGS AUTO DELIVERY START 5878 <br /> DISABLED DISABLED <br /> LINE PERIODIC WARNINGS AUTO DELIVERY END <br /> DISABLED DISABLED PERIODIC TEST TYPE <br /> LINE ANNUAL WARNINGS AUTO EXTERNAL INPUT ON STANDARD <br /> DISABLED DISABLED <br /> AUTO EXTERNAL INPUT OFF ANNUAL TEST FAIL <br /> PRINT TC VOLUMES DISABLED ALARM DISABLED <br /> ENABLED AUTO SENSOR FUEL ALARM <br /> DISABLED PERIODIC TEST FAIL <br /> TEMP COMPENSATION AUTO SENSOR WATER ALARM ALARM DISABLED <br /> VALUE (DEG F ) : 60.0 DISABLED <br /> STICK HEIGHT OFFSET AUTO SENSOR OUT ALARM GROSS TEST FAIL <br /> DISABLED DISABLED ALARM DISABLED <br /> H-PROTOCOL DATA FORMAT ANN TEST AVERAGING: OFF <br /> HEIGHT PER TEST AVERAGING: OFF <br /> DAYLIGHT SAVING TIME <br /> ENABLED TANK TEST NOTIFY: OFF <br /> START DATE RS-232 SECURITY <br /> APR WEEK 1 SUN CODE : 000000 TNK TST SIPHON BREAKOFF <br /> START TIME <br /> 2:00 AM DELIVERY DELAY 5 MIN <br /> END DATE <br /> OCT WEEK 6 SUN <br /> END TIME <br /> 2:00 AM RS-232 END OF MESSAGE <br /> DISABLED <br /> RE-DIRECT LOCAL PRINTOUT <br /> DISABLED <br /> SYSTEM SECURITY <br /> CODE : 000000 <br /> LEAK TEST METHOD <br /> TEST WEEKLY : ALL TANK <br /> SUN <br /> START TIME : 12:00 AM <br /> TEST RATE :0.20 GAL/HR <br /> DURATION 2 HOURS <br /> LEAK TEST REPORT FORMAT <br /> NORMAL <br />