REMOVAL_2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ALMENDRA
>
8650
>
2300 - Underground Storage Tank Program
>
PR0528353
>
REMOVAL_2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:37 AM
Creation date
11/2/2018 9:26:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2008
RECORD_ID
PR0528353
PE
2361
FACILITY_ID
FA0019141
FACILITY_NAME
GMAC MORTGAGE LLC
STREET_NUMBER
8650
Direction
W
STREET_NAME
ALMENDRA
STREET_TYPE
WAY
City
TRACY
Zip
95376
APN
24811024
CURRENT_STATUS
02
SITE_LOCATION
8650 W ALMENDRA WAY
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\ALMENDRA\8650\PR0528353\REMOVAL.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
163
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.. <br />..i <br />SAMPLING PROTOCOL FOR ROUTINE TANK REMOVALS <br />The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be representative <br />of native soils beneath the tank's invert (tank's bottom) at a collection depth not to exceed 2 - 4 feet. If contamination is documented <br />during closure, an Unauthorized Release Notification must be completed and submitted within five (5) working days pursuant to <br />California Health & Safety Code, Section 25295. <br />WATER NOT PRESENT IN THE TANK PIT <br />TANK <br />TANK SIZE <br />MINIMUM NUMBER <br />LOCATION OF SOIL SAMPLES <br /># <br />(Gallons) <br />of SOIL SAMPLES <br />2 from wall next to tank <br />< 1,000 <br />1 per Tank <br />FF7illOR pump End ofTank <br />r.r. <br />1,000 - 10,000 <br />2 er Tank <br />1 at each End of Tank <br />> 10,000 <br />3 or More <br />Ends and Middle OR generally <br />per Tank <br />spaced along the length of the Tank <br />DIDIN!_ ANn CTnf KPi7.F. <br />PIPING SOIL SAMPLES <br />I Sample every 20 lineal feet <br />TANK & PIPING STOCKPILE SAMPLES <br />2 Samples every 50 cubic yards <br />m, mWn re DDDQTi NT IN TANK PTT <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION of SOIL <br />SAMPLES <br />MINIMUM NUMBER <br />of WATER SAMPLES <br />(Gallons) <br />< 10,000 <br />2 from wall next to tank <br />< 1,000 <br />3 per Tank <br />Single Tank <br />3 <br />ends at soil/groundwater <br />I <br />Center and Ends OR Sides of Tank <br />> 10,000 <br />interface & 1 below tank <br />Ends and Middle and generally spaced <br />4 from wall next to tank <br />> 10,000 OR <br />ends at soil/groundwater <br />1 <br />Tank Cluster <br />5 or more <br />interface & 1 below each <br />tank <br />SLAB PRESENT IN THE TANK PIT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in order to <br />collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />TANK <br />TANK SIZE <br />MINIMUM NUMBER <br />LOCATION of SOIL SAMPLES <br /># <br />(Gallons) <br />of SOIL SAMPLES <br />< 1,000 <br />3 per Tank <br />Center and Ends OR Sides of Tank <br />1,000 - 10,000 <br />5 per Tank <br />Center and Ends OR Sides of Tank <br />> 10,000 <br />5 OR More per Tank <br />Ends and Middle and generally spaced <br />along the length of the Tank <br />EH 23 046 (Revised 12/31/07) <br />
The URL can be used to link to this page
Your browser does not support the video tag.