My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
E
>
103
>
2300 - Underground Storage Tank Program
>
PR0231555
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2021 10:12:29 PM
Creation date
11/4/2018 2:07:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231555
PE
2361
FACILITY_ID
FA0004027
FACILITY_NAME
HENDRIX FORK LIFT INC
STREET_NUMBER
103
Direction
N
STREET_NAME
E
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15318001
CURRENT_STATUS
02
SITE_LOCATION
103 N E ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\E\103\PR0231555\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
11/9/2012 8:00:00 AM
QuestysRecordID
88768
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA '� <br /> STATE WATER RESOURCES CONTROL BOARD i d� o 0 <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B � . <br /> I <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE ITEMEl 2 INTERIM PERMIT ® 4 AMENDED PERMIT ❑ B TEMPORARY TANK CLOSURE S TANK REMOVED <br /> DBAOR FACILITY NAME WHERE TANK IS INSTALLED: A. TeiChert & Son, Inc. 3 , . <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-�SPPECIFY IF UNKNOWN <br /> A OWNER'S TANK 1.0.# C-11 South I*- B. MANUFACTURED BY: Unknown <br /> C. DATE INSTALLED(MO/DAWYEAR) 19 7 2 D. TANK CAPACITY IN GALLONS: 20, 000 <br /> II.TANK CONTENTS IFA-11S MARKED,COMPLETE ITEM C. <br /> A ® 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. 18 REGUTAP UNLEADED ® 3 DIESEL ❑ S AVIATION GAS <br /> 2 PETROLEUM ❑ 60 EMPTY 1 PRODUCT ❑ 1b PREMUM UNLEADED ❑ 4 GASOHOL ❑ 7 METHANOL <br /> ❑ ❑ 1e MIDGRADE UNIFADEDn�`–� S JET FUEL ❑ 8 MBS <br /> ❑ 3 CHEMICALPRODUCT ❑ 95 UNKNOWN E:] 2 WASTE ❑ 2 LEADED u 99 OTHER(DESCRIBE N TEND.BELON? <br /> D. IF(Al)IS NOT MARKED. ENTER NAME OFSUBSTANCE STORED C.A.S-# <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL O 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM ® 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ® 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ B 100% METHANOL COMPATBLE W/FRP <br /> (P,I-q Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ i RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING ® 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ® 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> E SPILL AND OVERFILL.BLF SPILL CONTAINME STALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE VES NO_ STRIKER PLATE VES_ NO DISPENSER CONTAINMENT VES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A(U> PRESSURE A U 3 GRAVITY A U 4 FLEXIBLEPIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 9 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U a 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ®1 KQWflC UNE tEAK O 2 ME TIOMNE95 O 3 CONIINUmS IMER3TIT91 �4 RECfRONN UNE O 5 AUfOMATC mw � 99 OTHER <br /> 9EIE" TESnW AgwO LEAK 6EIECTOR 9aDDOWp <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ® 2 MANUAL RECONCILIATION RY ❑ 3 MONITORING ❑ 4 AUTOMATIGAUGING MONITORING <br /> TANK ❑ 5 MOONTORINGROUND TER ❑ 6 ANNUALTESTING <br /> ❑ 7 <br /> MONITORING INTERSTITIAL O 6 SIR ❑ 9 WEETANKLY MANUAL ❑10 MONTHLY <br /> TANK ❑ 95 UNKNOWN ❑99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED D TE LAST UDSR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES NO <br /> SUB STA NCE REMAINING GALLONS INERT MATERIAL ❑ <br /> THIS FOdM HAS B EN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAME I DATE <br /> (PRIMED 631ONATURE) George Takemori 12-1-98 <br /> LOCAL AGENCY USE ONL THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY#1" TANK# <br /> STATE LD:# m <br /> PERMIT NUMBER PERMIT APPROVED BYMATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY PERMIT APPLICCATION-FORMA,UNLESS A CURRENT FORMA HAS BEEN FILED, FDRM C MUST BE COMPLETED FOR INSTALLATIONS.THISFORI <br /> SHOULD BE ACCOMPANIED BY A PLOT P 9LE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING TH' "RGROUND STORAGE TANK REGULApTITIONS ' <br /> FORM 8 (6-95) �� �. — 4t/ 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.