My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EDISON
>
405
>
2300 - Underground Storage Tank Program
>
PR0515742
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2021 10:20:38 PM
Creation date
11/4/2018 2:11:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0515742
PE
2361
FACILITY_ID
FA0010849
FACILITY_NAME
FOWLERS BODY SHOP
STREET_NUMBER
405
Direction
N
STREET_NAME
EDISON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
135-460-06
CURRENT_STATUS
02
SITE_LOCATION
405 N EDISON ST
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\EDISON\405\PR0515742\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/9/2014 6:02:41 PM
QuestysRecordID
92880
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> VL PIPING. NS UCTON(ChopkadtlutaPp" <br /> UNOERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ❑,e.t 1�PRESSURE 112, SUCTION 3. GRAVITY 1:11. PRESSURE 132. SUCTION ❑ 3. GRAVITY <br /> CONSTRUCTIOW 9--f-SINGLE WALL ❑ 3. LINEOTRENCH ❑99. OTHER ❑ 1. SINGLE WALL ❑95, UNKNOWN <br /> MANUFACTURER ❑ 2, DOUBLE WALL ❑85. UNKNOWN ❑ 2. DOUBLE WALL ❑N. OTHER <br /> MANUFACTURER MANUFACTURER' <br /> I&1.BARE STEEL ❑ S. FRP COMPATIBLE WI 1M%METHANOL ❑ 1. BARE STEEL ❑ B. FRP COMPATIBLE WI 1M%METHANOL <br /> MATERIALS AND ❑ 2. STAINLESSSTEEL ❑ T. GALVANIZED STEEL ❑ 2. STAINLESS STEEL ❑ T. GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION ❑ 3. PLASTIC COMPATIBLE WITH CONTENTB 1195. UNKNOWN ❑ 5. PLASTIC COMPATIBLE WITH CONTENTS 11 B. FLEKIBLE(NOPE) ,❑98. OTHER <br /> ❑ 4. FIBERGLASS ❑ 8. FLEKIBLE(MOPE) ❑99, OTHER ❑ 4. FIBERGLASS ❑ 9, CATHODIC PROTECTON <br /> ❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION ❑ 5. STEEL Val COATING. ❑95. UNKNOWN <br /> NI.PIPING LEAK DETECTION(Check W Map appM <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING v K f a w��a PRESSURIZED PIPING(Chack ep tMf apply);SINGLE WALL PIPING <br /> SINGLE ALL PIPING(Chock ed that apply): 1%(��W <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPM TEST VATH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPM TEST WITH AUTO PUMP SHUT OFF FOR LEAK. <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION-AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION;AUDIBLE AND VISUAL ALARMS <br /> ALARMS <br /> 132 MONTHLY 0.2 GPM TEST 11MONTHLY 0.2 GRH TEST <br /> 111 3.ANNUAL INTEGRITY TEST(0.1 GRH) <br /> ❑ 3. ANNUAL INTEGRITY TEST JO.1 GPM) <br /> ❑ {. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTON SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Chock all fMl apply): <br /> ❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM I TRIENNIAL PIPING INTEGRITY ❑ S. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(D.I GPM) ❑ S. TRIENNIAL INTEGRITY TEST(C 1 GPM) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING)+ SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING) <br /> ❑ T. SELFMONITOMNG ❑ T. SELFMONITORING <br /> GRAVITY FLOW'. GRAVITY FLOW(Chock ad But appy): <br /> ❑ 9 BIENNIAL INTEGRITY TEST(0.1 GPM) ❑ S. DAILY VISUAL MONITORING <br /> ❑ B. BIENNIAL INTEGRITY TEST(0 1 GPM) <br /> SECONOARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Chock ad fiat appy): PRESSURIZED PIPING(ChacF all that appy): <br /> 10. COM4INM US TURBINE BUMP SENSOR W1TM AUDIBLE AND VISUAL ALARMS AND <br /> C10.CONTINUOUS TURBINE SUMP SENSOR`MTM AUDIBIF AND VISUAL ALARMS AND Irrapk am) <br /> ❑ e. AUTO PUMP SHUTOFF WHEN A LEAK OCCURS ❑ a. AUTOPUMPSHUTOFFWMENALEAKOCCURS <br /> ❑ b AUTO PUMP SHUT OFF FOR LEAKS.SYSTEM FAILURE AND SYSTEM ❑ 0, AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ e NO AUTO PUMP SHUT OFF <br /> ❑ 11 AUTOMATIC LINE LEAK DETECTOR(10 GPM TEST)WITH FLOW SHUT OFF OR ❑ Tl.AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPM) ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPM) <br /> SUCTIONIGRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM' <br /> ❑ 13. CONTINUOUS SUMP SENSOR-AUDIBLE AND VISUAL ALARMS ❑ 11 CONTINUOUS SUMP SENSOR♦AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check atl that appy) EMERGENCY GENERATORS ONLY(Chock as Mat apply) <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF.AUDIBLE AND ❑ N. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUALALARMS ALARMS <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST)WITHOUT FLOW SHUT OFF OR ❑ 15. AUTOMATIC UNE LEAK DETECTOR 110 GPM TESTI <br /> RESTRICTION <br /> ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPM) ❑ 14. ANNUAL INTEGRITY TEST(0.1 GPM) <br /> 1312. DAILY VISUAL CHECK ❑ , DAILY VISUALCHECK <br /> VIS..DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE t. a!/1N � 134, DAILYVISUALCHECK <br /> DATE INSTALLED ❑ 2. CONTINUOUS DISPENSER PAN SENSOR•AUDIBLE AND VISUAL ALARMS Y f�,vA ❑ S. TRENCH LINER/MONITORING <br /> ❑ 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER-AUDIBLE AND VISUAL ALARMS ❑e. NONE <br /> IX OWNERIOPERATOR SIGNATURE <br /> I party tlu ah viaaa apurna 0 ew best a M knR.W,. <br /> SIG F DATE 1-3 <br /> NAMEOFOANEROPERATOR(pppB TITLE OF OWNERIOPBR•�A�T(ORW/ •},/ (i/�� <br /> PamiM1Nw b@r(w/waluw Phly) '1 Pam111 AppIwaU(FotPopluw <br /> way) Pemnl E�Ira9pn MIs(Fwroal uas way) <br /> CUPAFORM(4/99) I Formerly SWRCB Form 8 <br />