My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
INSTALL_2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:30 PM
Creation date
11/4/2018 2:26:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2013
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DANIELS\2440\PR0527629\INSTALL PLAN 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BCE #12919 <br /> BCE #10050 <br /> San Joaquin County <br /> Environmental Health Department DIRECTOR <br /> ?' =.Ef''•P Donna Heran,REHS <br /> r.' 1868 East Hazelton Avenue <br /> PROGRAM COORDINATORS <br /> a; Stockton, California 95205-6232 Robert McClellon,REHS <br /> Jeff Carruesoo,REHS,RDI <br /> • �y• .,,,,:.• ':° Website:www.sjgov.org/ehd Kasey Foley,REHS <br /> C r F o Ra <br /> Phone: (209) 468-3420 Linda Turkatte,REHS <br /> Fax: (209) 464-0138 <br /> December 12, 2012 <br /> Alexia Inigues, Project Planner <br /> Barghausen Consulting Engineers, Inc. <br /> 18215 72nd Avenue South <br /> Kent, WA 98136 <br /> Re: Costco Gasoline#10312440 Daniels Street, Manteca, 95337 SR0066048 <br /> Costco Gasoline#658 3250 West Grant Line Road, Tracy, 95377 SR0066165 <br /> The San Joaquin County Environmental Health Department (EHD) has reviewed the permit <br /> application for a new installation of an underground storage tank (UST) system at the above <br /> noted address. In order for this permit application review to continue, a detailed addendum and <br /> revised sheets for plans must be provided for the following deficiencies: <br /> 1. Page 4 of the Application for Underground Storage Tank Installation Permit indicates <br /> that Enhanced Leak Detection (ELD) must be performed prior to the final inspection. A <br /> separate permit application is required to install ELD. Submit the required application <br /> and fees. <br /> 2. Page 7 section G of the Application for Underground Storage Tank Installation Permit <br /> lists an OPW 61fSTOP-2000 as the overfill prevention at 95%. However, an <br /> OPW61fSTOP is approved for aboveground storage tanks. Choose equipment that is <br /> approved for underground storage tanks. Correct the discrepancies. Submit corrected <br /> version. <br /> 3. Page 7 section G of the Application for Underground Storage Tank Installation Permit <br /> indicates that an approved overfill prevention device must be provided at each tank fill <br /> location. Choose one of the following methods. You may refer to the State Water <br /> Resources Control Board Letter of Guidance 150-2. Submit corrected version. <br /> 4. Page 8 Section I of the Application for Underground Storage Tank Installation Permit <br /> lists the electronic monitoring of the interstitial space as a single float Veeder-Root <br /> 794380-301. Sheet C3 of the Underground Tank Installation Site Plan, item in circle 9 <br /> states a dual float sensor would be installed. Sheet T2 of the Sump Installation Details, <br /> item hexagon 22 illustrates an image of a dual float sensor. Sheet T5, item hexagon 22 <br /> documents single float sensor Veeder-Root 794380-302 would be installed. Item 33 of <br /> Fueling System Catalog Cut Sheets highlighted the single float sensor Veeder-Roof <br /> 794380-301.This location requires a dual float sensor. Correct the discrepancies. Submit <br /> corrected version. <br /> 5. Operating Permit Application Lubrizol Tank Information/ UPCF UST-B should specify <br /> contents as Lubrizol, not fuel additive. <br />
The URL can be used to link to this page
Your browser does not support the video tag.