Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department DIRECTOR <br /> Donna Heran, REHS <br /> 2' 1868 East Hazelton Avenue <br /> '( Stockton, California 95205-6232 PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco, RENS,RDI <br /> Kase Foley, REHS <br /> aiiFoaN _ Website: : (209)468-3 20 Linda Turk tte, REHS <br /> Phone: (209) 468-3420 <br /> Fax: (209) 464-0138 <br /> December 12, 2012 <br /> Alexia Inigues, Project Planner <br /> Barghausen Consulting Engineers, Inc. <br /> 1821572 nd Avenue South <br /> Kent, WA 98136 <br /> Re: Costco Gasoline#10312440 Daniels Street, Manteca, 95337 SR0066048 <br /> Costco Gasoline#658 3250 West Grant Line Road, Tracy, 95377 SR0066165 <br /> The San Joaquin County Environmental Health Department (EHD) has reviewed the permit <br /> application for a new installation of an underground storage tank (UST) system at the above <br /> noted address. In order for this permit application review to continue, a detailed addendum and <br /> revised sheets for plans must be provided for the following deficiencies: <br /> 1. Page 4 of the Application for Underground Storage Tank Installation Permit indicates <br /> that Enhanced Leak Detection (ELD) must be performed prior to the final inspection. A <br /> separate permit application is required to install ELD. Submit the required application <br /> and fees. <br /> 2. Page 7 section G of the Application for Underground Storage Tank Installation Permit <br /> lists an OPW 61fSTOP-2000 as the overfill prevention at 95%. However, an <br /> OPW61fSTOP is approved for aboveground storage tanks. Choose equipment that is <br /> approved for underground storage tanks. Correct the discrepancies. Submit corrected <br /> version. <br /> 3. Page 7 section G of the Application for Underground Storage Tank Installation Permit <br /> indicates that an approved overfill prevention device must be provided at each tank fill <br /> location. Choose one of the following methods. You may refer to the State Water <br /> Resources Control Board Letter of Guidance 150-2. Submit corrected version. <br /> 4. Page 8 Section I of the Application for Underground Storage Tank Installation Permit <br /> lists the electronic monitoring of the interstitial space as a single float Veeder-Root <br /> 794380-301. Sheet C3 of the Underground Tank Installation Site Plan, item in circle 9 <br /> states a dual float sensor would be installed. Sheet T2 of the Sump Installation Details, <br /> item hexagon 22 illustrates an image of a dual float sensor. Sheet T5, item hexagon 22 <br /> documents single float sensor Veeder-Root 794380-302 would be installed. Item 33 of <br /> Fueling System Catalog Cut Sheets highlighted the single float sensor Veeder-Root <br /> 794380-301.This location requires a dual float sensor. Correct the discrepancies. Submit <br /> corrected version. <br /> 5. Operating Permit Application Lubrizol Tank Information/ UPCF UST-13 should specify <br /> contents as Lubrizol, not fuel additive. <br />