Laserfiche WebLink
LUBRIZOL® 9888 <br /> 5 Fire Fighting Measures <br /> Flash Point 32°C,89.6-F PMCC(Typical) <br /> Extinguishing Media CO2,dry chemical,or foam.Water can be used to cool and protect exposed material. <br /> Firefighting Procedures Recommend wearing self-contained breathing apparatus.Water may cause splattering. <br /> Unusual Fire&Explosion Hazards Toxic fumes,gases or vapors may evolve on burning.Vapors may be heavier than air and may travel along the ground to a <br /> distant ignition source and flash back Container may rupture on heating.See section 10 for additional information. <br /> 6 1 Accidental Release Measures <br /> Spill Procedures May form explosive mixtures with an.immediately evacuate all personnel from danger area Personal Protective Equipment <br /> must be worn,see Personal Protection Section for PPE recommendations.Take precautions to avoid release to the <br /> environment.Eliminate all sources ofheat,sparks plot lights,static electricity and open flames.Ventilate spill area Prevent <br /> entry into sewers and waterways,dispose of in accordance with all federal,state and local environmental regulation.Pick up <br /> free liquid for recycle and/or disposal if can be accomplished safely with explosion proof equipment.Residual liquid can be <br /> absorbed on inert material.Check under Transportation and Labeling(DOT/CERCLA)and Other Regulatory information <br /> Section(SARA)for hazardous substances to determine regulatory reporting requirements for spills. <br /> 7 1 Handling and Storage <br /> Pumping Temperature Not determined. <br /> Maximum Handling Temperature Not determined. <br /> Handling Procedures Keep away from ignition sources such as heat,sparks and open flame.No smoking.Keep containers closed when not in <br /> use.Do not discharge into drains or the environment,dispose to an authorized waste collection point.Use appropriate <br /> containment to avoid environmental contamination.Avoid breathing dust;fimme,gas,mist,vapors or spray.Ground/bond <br /> container and receiving equipment.Use explosion-proofequipmem Take precautionary measures against static discharge. <br /> Use only non-sparking tools.Use only outdoors or in a well-ventilated area Wash thoroughly after handling.Launder <br /> contaminated clothing before reuse.Empty containers retain material residue.Do not cut,weld braze,solder,drill,grind or <br /> expose containers to heat,flame,spark or other sources of ignition.Dispose of packaging or containers in accordance with <br /> local,regional,national and internationalregulations. <br /> Maximum Storage Temperature Not determined <br /> Storage Procedures Do not store near potential sources of ignition.Isolated outside storage is preferred.Inside storage area should be in a <br /> flammable liquids cabinet or storage area.Take precautions to avoid release to the environment Store in a well-ventilated <br /> place.Keep cool.Keep container tightly closed.See section 10 for incompatible materials. <br /> Maximum Loading Temperature Not determined <br /> 8 Exposure Controls/Personal Protection <br /> Exposure.Limits <br /> Xylene 100 plant N/E 100 ppm 150 ppm N/E N/E <br /> Ethyl benzene 100 ppm N/E 100 ppm 125 ppm N/E N/E <br /> Petroleum naphtha N/E N/E N/E N/E 100 ppm(1) N/H <br /> Naphthalene 10 ppm N/E 10 ppm(s) 15 ppm N/E N/E <br /> Toluene 200 ppm 300 ppm(c) 20 ppm N/E N/E N/E <br /> (s)-Skin exposure <br /> (p)-Proposed limit <br /> (c)-Ceiling exposure <br /> (1)-Recommended exposure limit <br /> (u)-Supplier recommended exposure limit <br /> (N/E)-None established <br /> Other Exposure Limits None known. <br /> Engineering Controls Use local exhaust ventilation to control trusts or vapors.Additional ventilation or exhaust may be required to maintain air <br /> concentrations below recommended exposure limits.Use explosion proof equipment <br /> Gloves Procedures Viton.Teflon.Polyvinyl alcohol.Note:polyvinyl alcohol gloves are water soluble and should not be used when there is <br /> potential for water contact. <br /> Eye Protection Safety glasses.If potential for splash or mist exists,wear chemical goggles or fsceshield <br /> Respiratory Protection Use NIOSH/MSHA approved full face respirator with a combination organic vapor and high efficiency filter cartridge if the <br /> recommended exposure limit is exceeded.Use self-contained breathing apparatus for entry into confined space,for other <br /> poorly ventilated areas and fm large spill clean-up sites.Consult with an industrial hygienist to determine the appropriate <br /> respiratory protection for your specific use of this material.A respiratory protection program compliant with all applicable <br /> regulations must he followed whenever workplace conditions require the use of a respirator. <br /> Clothing Recommendation Gloves,coveralls,apron,boots as necessary to minimize contact.Wear a chemically protective apron when contact with <br /> material may occur.Do not wear rings,watches or similar apparel that could entrap the material and cause a skin reaction. <br /> Launder contaminated clothing before reuse. <br /> Page 2/6 <br />