My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
INSTALL_2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:30 PM
Creation date
11/4/2018 2:26:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2013
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DANIELS\2440\PR0527629\INSTALL PLAN 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Issue Date:November 22,1995 <br /> Revision Date:March 24,2011 <br /> 2nd Revision lune 23,2011 <br /> Franklin Fueling Systems <br /> (originally listed as FE Petro, Inc.) <br /> STP-MLD-D Pipeline Leak Detector <br /> AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br /> Certification Leak rate of 3.0 gph with PD = 100%and PFA = 0%. <br /> Leak Threshold 2.0 gph. <br /> A pipeline system should not be declared tight if the test result indicates a loss that <br /> equals or exceeds this threshold. <br /> Applicability Diesel and Ultrazol 9888 <br /> Specification System tests steel and fiberglass pipelines. <br /> Tests are conducted at operating pressure. <br /> Pipeline Maximum for rigid system is 341 gallons. <br /> Capacity <br /> Waiting Time None between delivery and testing. <br /> None between dispensing and testing. <br /> Test Period Average response time is I minute. <br /> System Permanent installation on pipeline. <br /> Features Automatic testing of pipeline. Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> Restricted flow to dispenser if leak is declared. <br /> Calibration System must be checked annually and, if necessary, calibrated in accordance with <br /> manufacturer's instructions. <br /> Franklin Fueling Systems Evaluator: Ken Wilcox Associates <br /> 3760 Marsh Road Tel: (816) 443-2494 <br /> Madison, WI 53718 Date of Evaluation: 04/30/94 Rev. 06/23/11 <br /> Tel: (800) 225-9787 <br /> E-mail: info@franklinfueling.com <br /> URL: www.franklinfueling.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.