My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
INSTALL_2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:30 PM
Creation date
11/4/2018 2:26:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2013
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DANIELS\2440\PR0527629\INSTALL PLAN 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F. SYSTEM PIPING CONTINUED: I.W BCE#12919 <br /> Check CC <br /> Box Section <br /> ❑X HSC .1 c 1 Piping compatible with material intended to be stored. <br /> 25290.2 c 1 <br /> 23 CCR <br /> 2631(b) Desi nand construction of ipin a roved b Inde endent testing organization e. . UL . <br /> IX Piping,including vent lines,sloped toward tanks with minimum 1/4 inch sloe per 1 foot of run. <br /> HSC <br /> CK 25290.11.2 c kj ) Vapor recovery,fill riser,and vent line piping are secondarily contained. <br /> G. OVERSPILL/OVERFILL PREVENTION: <br /> Check Cod <br /> Box Section <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> IX 2635(b) Manufacturer OPW Model <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> X Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flaw to the tank at least 30 minutes before the tank overfills,provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity;and activate an <br /> E{ 2635(b)(2) audible alarm at least five minutes before the tank overfills <br /> ❑ Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer Veeder-Root Model Overfill Alarm#790091-002;with Level Gauge#846391- 01 <br /> H. CORROSION PROTECTION: <br /> Check Code <br /> Box Section <br /> IX Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br /> 23 CCR ❑ Steel isolated from contact with backfill <br /> 2636(b) <br /> [{FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: ❑ Sacrificial Anode <br /> [X 23 CCR ❑ Steel tank with field installed cathodic protection or impressed <br /> 2635(a)(2) <br /> current <br /> Tie-downs,when used, constructed of non-corrosive material or coated steel. (Tar Coat Epoxy) <br /> Revised 8/1/11 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.