My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2023 10:45:22 AM
Creation date
11/4/2018 2:28:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DANIELS\2440\PR0527629\BILLING 2013 - 2014.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L-J-- Tr��+✓1 J <br /> IED PROGRAM CONSOLIDATED FO <br /> UNDERGROUND STORAGE TANK <br /> .,/ MONITORING PLAN - (Pae I of 2) <br /> TYPE OF ACTION u I.NEW PLAN ❑ 2.CHANGE OF INFORMATION 490-1 <br /> PLAN TYPE L MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2. <br /> (Cheek one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) 1 <br /> BUSINESS NAME(Same as Facility Name or DBA) ' <br /> Coscto Gasoline Loc . No. TBD, Manteca, CA <br /> BUSINESS SITE ADDRESS 103 CITY 101 <br /> 2440 Daniels Street Manteca <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by the equipment manufacturers'instructions,or annually,whichever is more freuq ent.Such work must be performed by qualified personnel.[23 CCR§2632,2634.2638,26411 <br /> MONITORING EQUIPMENT IS SERVICED At least N(L ANNUALLY �99.OTHER(Sped Per Mfrs. Instrs.490-3a <br /> fy)� 490--3b. <br /> III. MONITORING LOCATIONS <br /> L NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ❑ 2.SITE PLOT PLANIMAP PREVIOUSLY SUBMITTED [23 CCR§2632,2634] 490-4. <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) fh heak� y <br /> I.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490-5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,26341 <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY 5�f b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-6 <br /> PANEL MANUFACTURER: Veeder Root 490.7 MODEL#: TLS-3 5 OR 4W-8 <br /> LEAK SENSOR MANUFACTURER: Veeder Root 490-9. MODEL#(S): 794380-303 490-io. <br /> 2.A UTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S)-[^-_CCR§2643] ago-11- <br /> PANEL MANUFACTURER: 490-12. MODEL#: 490-13. <br /> IN-TANK PROBE MANUFACTURER: 490-14. MODEL#(S): 490-15. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILYANIGHTLY ❑ c.WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17. <br /> PROGRAMMED TESTS: _ ❑ ❑ b.0.2 h. ❑ c.OTHERS ci 0-90 18. <br /> a.0.( <br /> g---p�h. g.p.h. ( Pe fY}: <br /> 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 CCR§2646.1] _-� 490-20. <br /> ❑ 0-21 <br /> 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§26451 TESTING PERIOD: F_] a.36 HOURS El b.60 HOURS 490-22, <br /> 5.TANK INTEGRITY TESTING PER[23 CCR§2643.11 ago-z3. <br /> TEST FREQUENCY: [;r ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): ago-z4. <br /> a. _P fY)_. _ a9o_zs� <br /> �99,OTHER(Specify): Tank Probe VR-847390-109; Ball Float 900- Capacity Fill Point 4W-2277-26. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) h(Checkall <br /> that at app <br /> fv <br /> 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490-28. <br /> [23 CCR SECONDARY CONTAINMENT IS: ❑ a.DRY db.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-29. <br /> §2636] <br /> PANEL MANUFACTURER: Veeder Root 490-30 MODEL 9: TLS-350R 490-31. <br /> LEAK SENSOR MANUFACTURER: Veeder Root 490-32. MODEL#(S): 794380,-3 3 490-33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. In a.YES ❑ b.NO 490.34, <br /> FAILUREIDISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. d a.YES ❑ b.NO 490-35. <br /> F-12.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF 490-36. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 CCR§26361 <br /> 490-37. 490-38. <br /> MLLD MANUFACTURER(S): MODEL#(S): <br /> 3. ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 h.LEAK TESTS. 23 CCR§2636 490-39 <br /> ELLD MANUFACTURER(S): Veeder Root 440-M10 MODEL#(S): 848480-001 490-41. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 490-42 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. 9 a.YES ❑ b.NO 440-43 <br /> ELLD FAILUREIDISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. [vra.YES ❑ b.NO 49044 <br /> - <br /> 490-45. <br /> 4.PIPE INTEGRITY TESTING. <br /> a9aa6. <br /> TEST FREQUENCY: SK a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify)- 199.47 _ <br /> 5. VISUAL PIPE MONITORING. � 490-4a. <br /> ( <br /> FREQUENCY: wlw� a.DAILY ❑ b.WEEKLY ❑ c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 490-49 <br /> .Allowed for monitorin 4f unburied emerged generator Fuel_Qipingon1y�HSC§25281 b a)- <br /> ❑ 490-50 <br /> 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.[23 CCR§2636(a)(3)] T <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490 s 1. <br /> 0-90-52 <br /> ❑ 99.OTHER(Specify) 490-53. <br /> UPCF UST-D(12/2007)-114 www.unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.