Laserfiche WebLink
E <br />0 <br />Page z Or 6 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www sigov orglehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: Facility Address: Duro: <br />Costco Wholesale #1031 <br />2440 Daniels ST, Manteca August 18, 2016 <br />On Site Records <br />204 <br />CCR 2712(1) <br />Current monitoring plan approved by the EHD not found on site _ V R COS <br />Failure to have an approved UST response plan available onsite <br />205 <br />CCR 2712(1) <br />206 <br />CCR 2712 <br />V R COS <br />Failure to comply with UST operating permit conditions <br />207 <br />HSC 25294 <br />-V R -COS <br />Failed to record unauthorized release from primary containment <br />208 <br />CCR 2650(e) <br />V - R :. COS <br />Failed to notify the EHD of a reportable unauthorized release <br />209 <br />CCR 2715(c) <br />.V ::R sCOS <br />Designated operator did not inspect all required items and/or the inspection reports <br />not completed ■ V = R = COS <br />211 <br />CCR 2715(e) <br />Designated operator monthly inspection reports not maintained on site for at least 12 months <br />211 <br />CCR 27150 <br />-V �R -COS <br />Designated operator employee training not performed or log not kept <br />212 <br />CCR 2715(()(2) <br />- V = R -: COS <br />Unstaffed facility failed to have or implement a training program approved by the EHD <br />213 <br />HSC 25281.5(b)(2) <br />_ V .-. R =COS <br />Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />214 <br />HSC 25281.5(b)(3) <br />. V - R r. COS <br />Unburied emergency generator fuel piping not visually inspected at least monthly lag kept <br />or V R -. COS <br />UST System Observations <br />301 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills <br />and overfills <br />V R - COS <br />302 <br />HSC 25291(b) <br />UST system incapable of detecting leak from primary Into secondary containment (pre -Jul 2003) <br />303 <br />HSC 25290.2(d) <br />Monitoring system not maintained to detect entry Into secondary containment (Jul 2003 -Jun 2004) <br />. V _ R : COS <br />304 <br />HSC 25290Aii <br />Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) <br />= V R = COS <br />■ V = R r' COS <br />305 <br />HSC 25290.1(e) <br />VPH monitoring of the interstitial spaces of the UST system is not maintained_ <br />V :; R =COS <br />306 <br />CCR 2630(d) <br />Monitoring equipment is not installed or maintained to detect a leak at the earliest <br />opponunity <br />■ V - R ■ COS <br />307 <br />CCR 2632(c)Monitoring <br />system of the interstitial space of a double walled system not maintained <br />V_ R E COS <br />308 <br />intain a continuous monitoring system That activates an audible <br />EEJE <br />and visual alarm <br />�V r.R _COS <br />309 <br />sump f UDC failed to activate an audible and visual alarm or stop the flow product <br />310 <br />CCR 2636(0(5) <br />Piping is not fall -safe outside JUGS or fails to stop flow of product at dispenser inside UDCs <br />LV = R r. COS <br />311 <br />CCR 2638(a), 26410) <br />Failed to property program or operate leak detection equipment <br />= V - R _COS <br />- <br />7 V _ R COS <br />312 <br />CCR 26380 <br />Failed to affix a lag sticker on monitoring equipment certified, repaired, or <br />., <br />replaced <br />V R -. COS <br />313 <br />HSC 25290.1, 25290.2, <br />Failure to construct. operate, and maintain primary containment as product -light <br />:. V = R COS <br />314 <br />HSC 25290 1. 25290 2, <br />Failed to have secondary containment or secondary containment not tight <br />25291 <br />_ V .-, - COS <br />R <br />315 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed. and property disposed of (pre -Jul 2003) <br />316 <br />HSC 25290.1(c3). <br />Secondary containment not constructed to prevent water intrusion (after Jul 2003) <br />c V ; R -COS <br />25290.2(c3) <br />mV r: R ■ COS <br />317 <br />CCR 2636(0(2) <br />Line leak detector not installed <br />318 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />V =R -COS <br />■V �R ■COS <br />319 CCR <br />2635(b) <br />No spill bucket. railed to contain five gallons, or failed to provide a means to keep it empty <br />320 CCR <br />2635(b)(2) <br />Overfill prevention system not present or failed overfill <br />-COS <br />requirements <br />LV,- <br />321 CCR <br />2635(b)(2) <br />�tomeet <br />Overfill prevention was overridden <br />E <br />Page z Or 6 <br />