My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008 - 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
COMPLIANCE INFO_2008 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2023 10:47:25 AM
Creation date
11/4/2018 2:42:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2013
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DANIELS\2440\PR0527629\COMPLIANCE INFO 2009 - 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
308
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: w+rw.sjgov.org/ehd/unitiii.html <br />CONTINUATION FORM <br />Page: 3 of 3 <br />OFFICIAL INSPECTION REPORT <br />Date: 08118111 <br />Facility Address: Costco Wholesale #1031 2440 Daniels Street, Manteca <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />UST Inspection: Routine and Annual Monitoring System Certification <br />4. Financial responsibility documents have not been submitted to the EHD. Current financial <br />responsibility documents are required to be submitted annually. Complete and submit a copy of the <br />financial responsibility- <br />- Corrected on site. Received copies of CFR and insurance policy statement. <br />23d. The designated operator employee training for employees are either not performed within the <br />twelve months or have not been performed. It is unclear whether employees Elnidino Arreola, Regina <br />Hurtado, Caryn Hall have been performed. No previous training records could be found. <br />Last training for Yvette Bobadilla, Rodney Olivera, Sara Harris, Irwin Garcinia, Jules Lavroette was <br />conducted on 0312412010. The designated operator shall train facility employees or which he or she is <br />responsible in the proper operation and maintenance of the UST system once every 12 months. The <br />training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employees's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employees's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and <br />submit a statement how to ensure all employees are trained once every twelve months. <br />47. The UDC 7f8 annular sensor failed when tested. The sensors monitoring the liquid level in the <br />interstitial space shall be maintained so that a breach in the primary or secondary containment is <br />detected before the hazardous substance is released into the environment. Correct immediately by <br />having a properly licensed, trained, and certified contractor replace the failed component with a <br />functional component (LG 113-x listed, if applicable) and obtain a permit within one business day from <br />the EHD. <br />- Corrected on site. Sensor replaced on site. Ensure a permit is submitted to EHD within 1 business day. <br />Submit to SJC EHD within 30 days (09119111): <br />1. one copy of the completed "Return to Compliance Certification" form <br />2. a written corrective action statement for each of the above violation <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspe <br />Re i y: <br />Title <br />r <br />EHD 23-02-003 Rev 0711 0, <br />1 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.