Laserfiche WebLink
Veeder-Root Line Leak Aoation Guide 0 <br />Supported Pipe Types and Line Lengths* - TLS -350 Series Consoles <br />'lengths approved are for 3.0, 0.2, & 0.1 gph line leak tests using single pipe types. For mixed line types with PLLD, see footnote 1. <br />FIBERGLASS (24NCH) 10-500 10-500 10-775 10-775 25,000 0.204 <br />FIBERGLASS (3 -INCH) <br />10-220 <br />10-220 <br />10-350 <br />10.350 <br />35,000 <br />0.461 <br />STEEL (2 -INCH) <br />30-500 <br />30-500 <br />10-875 <br />10-675 <br />50,000 <br />0.190 <br />COPPER (1 -INCH, TYPE K) <br />FLEXIBLE PIPE - ADVANC E0 POLYMER <br />1.5 -INCH (P150SC) <br />10-500 <br />TECHNOLOOY <br />20-1100 <br />No <br />No <br />No <br />No <br />No <br />No <br />55,000 <br />8800 <br />0.041 <br />0.092 <br />1.75 -INCH (P175SC) <br />20-850 <br />No <br />No <br />No <br />7400 <br />0.125 <br />2.0 -INCH (P200SC) 20650 No No No 5600 0.163 <br />2.5 -INCH (P250SC) 20-430 No No No 4400 0.255 <br />DUALOY 3000/FLS III (1.5 INCH) <br />20-1100 <br />No <br />10-500 <br />10-500 <br />5400 <br />0.092 <br />DUALOY 3000IFLS 111 (2.0 INCH) <br />FNIVIRON <br />20-650 <br />No <br />10500 <br />10-500 <br />7600 <br />0.163 <br />FLEXIBLE PIPE - <br />GEOFLEX 11 or 0 (1.5 -INCH) <br />301100 <br />10-500 <br />10-500 <br />10500 <br />5700 <br />0.092 <br />GEOFLEX D (2 -INCH) <br />30-650 <br />No <br />10225 <br />10-225 <br />4500 <br />0.163 <br />GEOFLEX D (3 -INCH) <br />FLEXIBLE PIPE - FURON <br />30-300 <br />No <br />No <br />No <br />4100 <br />0.367 <br />oPW PISCES - SINGLE WALL <br />SP1 5 (1.5 INCH) <br />301100 <br />No <br />10-500 <br />10-500 <br />9000 <br />0.092 <br />SP20 (2 INCH) <br />30550 <br />No <br />10-225 <br />10-225 <br />7000 <br />0.163 <br />DPW PISCRS - DOUBLE WALL <br />CP15 (1.5 INCH) <br />10-1100 <br />No <br />10-500 <br />10-500 <br />17,500 <br />0.092 <br />CP15DW (1.5 INCH) 301100 <br />No <br />10500 <br />10600 <br />5400 <br />0.092 <br />CP20 (2 INCH) 30.650 <br />No <br />10-225 <br />10-225 <br />7600 <br />0.163 <br />WESTERN FIBERGLASS - DOUBLE WALL <br />COFLEX (1.5 INCH) 10-1100 <br />No <br />10-500 <br />10-500 <br />5400 <br />0.092 <br />COFLEX (2 INCH) 30-650 <br />No <br />10-225 <br />10225 <br />7600 <br />0.163 <br />SMARTFLEX (1.5 INCH) 20-1100 No No No 8600 0.092 <br />PETROTECHNIK UPP EXTRA (63 mm) 20-650 No No No 11,500 0.163 <br />RNVIROFLEX RETRACTABLE PIPE <br />PP1500 (1.5 -INCH) <br />PP1501 (1.5 -INCH) <br />PPI 502 (1.5 -INCH) <br />PP1503 (1.5 -INCH) <br />10-1100 10-500 10.600 10-500 2400 0.092 <br />101100 10-500 10-500 10500 3500 0.092 <br />101100 No 10-775 10-775 7300 0.092 <br />10-1100 No 10-225 10-225 2500 0.092 <br />PP2500 AND PP2501 (2.54NCH) No No 10-775 10775 - -^ <br />PP2502 (2.5 -INCH ) 10430 No 10225 10225 8700 0.255 <br />PP2503 (2.5 -INCH) 10-430 No 10225 10225 3100 0.255 <br />OMIFLEX COAXIAL PIPE <br />CP1601 (1.5 -INCH) 10-1100 10-500 10-500 10-500 13,000 0.092 <br />CP1503 (1.5 -INCH) 10.1100 No 10.500 10500 4500 0.092 <br />CP2503 (2.5 -INCH) 20430 No No No 3900 0.255 <br />'Mixed Piping Types with PLLD: Using software Version 23 or later, PLLD is certified far 3 gph-only testing for line volumes up to 212 gallons; and for 0.210.1 <br />gph testing for lane volumes up to 110 gallons. To determine the line volume for mixed piping types, multiply the line length (in feet) times the'gallonslfoot' value <br />for each pipe type and add the results. For example, site has 150 feet of 2" fiberglass and 50 feet of 3" fiberglass pipe: <br />Total line volume = [150 x 0.2041 + 150 x 0.4611 <br />= 30.6 + 23.1 <br />= 53.7 gallons <br />2The 0.2 and 0.1 gph line leak tests cannot be run on flex piping with WPLLD. <br />3Bulk Modulus entry is only applicable to consoles with software Version 23 or eater. Refer to the TLS System Setup manual (V -R PIN 576013-623) for program- <br />ming instructions. <br />51 <br />