Laserfiche WebLink
O V, <br /> g J <br /> ru <br /> io <br /> DPW 60VSPC-1001 VAPOR LINE VEEDER-ROOT 794380-323 W <br /> SHEAR VALVE ATTACH TO STABILIZER <br /> 88 98 NON-DISCRIMINATING POSITION SENSITIVE SUMP zZ <br /> MW V <br /> BAR OR STABILIZER SUPPORT. SENSOR SENSOR MOUNTED FLUSH TO BOTTOM o Q <br /> POSITION BASED ON VAPOR PUMP <br /> ALIGNMENT AND BEST CONNECTION. SHEAR VALVE MOUNTING BRACKET DISPENSER P Uj Z <br /> 96 AND PLATE TYP. OF (3) PER SUMP SKIN o <br /> CONDUIT STUP-UP GROUNDWIRE TO DISPEFRAMNSER 5� J F ®LL Q <br /> LOCATIONS (TYP.) - OPW 1OBHMP-5830 DOUBLE U-BOX (TYP.) o J LL <br /> ° 87 POPPET SHEAR VALVE PETROLEUM RESISTANT V (p CO Q W <br /> o (TYP. OF 2) PER SUMP. DISPENSER SKIN (TYP.) PTI TWIN TUBE SEALANT Z V Z <br /> o MIN. 1/4" BEAD CONT. <br /> ALL AROUND BETWEEN fl. Z Q <br /> 0 1" x 1" METAL PLATE FASTENERS AS REQUIRED F w <br /> DISPENSER U-BOX (TYP.) BY DISPENSERS MFG. FLANGES _ ® Q <br /> O (TYP-) zco Q <br /> O GROUNDWIRE 1'? T.O. ISLAND Q S 0 <br /> D 0 F5 R v <br /> JE LL <br /> (TYP.) a N y $ Q CJ o <br /> m 1/4" x 20 x 1-1/2" °, a /� Y Y Y oc Y cco <br /> DOUBLE WALL FRP (CONDUIT(ESSj 95 I "BRAVO" 3" F-33-D DW FRP LABEL: "GROUNDING TEST BOLT & DOUBLE NUT a d' REBARTURAL y y y ai � U W o <br /> DISPENSER SUMP TYP. 52 LOCATION' TYP. DOUBLE NUT TO MOUNT <br /> BONDED PENETRATION DOUBLE (TYP.) _ _ _ = <br /> WALL PENETRATION FITTING p GROUND WIRE (TYP,) ® Z 3 V <br /> (FACTORY INSTALLED TYP.) Uj <br /> DISPENSER SUMP <br /> v v 1"xl" METAL PLATE WALL ^ nco <br /> rl > > 55 61 SMITH FIBERCAST 3" OVER (NP ) GROUND DETAIL a AAW1 G1 <br /> a�z o IZ o Z O 2" FRP PIPING (TYP.) <br /> >}J 0- d FRONT VIEW OF DISPENSER SIDE VIEW OF DISPENSER <br /> a Sump Plan View Detail Two Product MPD Piping D Stage II Double-Nutted" Static Grounding o Dispenser Seal Detail <br /> T-6 SCALE: 1 "=V-0" T-6 NOT TO SCALE NOT TO SCALE <br /> HEALY PUMP 92 93 94 IN <br /> "SIDE 2" <br /> VAPOR FLOW METER 103 OPW IOBHMP-5830 DOUBLE POPPET $7 17 18 EXPLOSION PROOF 40-9/16" Uj <br /> VAPOR PRESSURE SHEAR VALVE (TYP. OF 2) PER SUMP. ELECTRICAL J-BOX <br /> 102 CONTRACTOR TO SECURE PRODUCT, VAPOR 20-1/4 Q p <br /> DISPENSER FRAME 85 SHEAR VALVE MOUNTING BRACKET <br /> SENSOR 99 AND ELECTRICAL PIPING TO INTERNAL 96 362 /$" (j) � W <br /> FACTORY BRINE RESERVOIR & I I DISPENSER BRACE WITH U-BOLTS PER EXPLOSION PROOF ELECTRICAL AND PLATE (TYP.) W O) <br /> SENSOR (BY OTHERS). POSITION 42 MANUFACTURERS INSTRUCTIONS (TYP.) SEAL-OFF, 6" ABOVE HIGHEST 1" CONDUIT FOR DISPENSER 28- /4' J ® a <br /> PER MANUFACTURER SUMP PENETRATION (TYP.) G POWER AND COMMUNICATION 14-3/8" (4) 13/16 X 1-7/16 0 3 <br /> OPW 60VSPC-1001 VAPOR LINE SHEAR DISPENSER SEAL LOCATED THIS SIDE ANCHOR BOLT SLOTS <br /> RECOMENDATIONS (TYP.) i I 88 VALVE ATTACH TO STABILIZER BAR OR FACTORY SUPPLIED BRINE RESERVOIR & T-6 3 _ <br /> STABILIZER SUPPORT. POSITION BASED SENSOR (BY OTHERS). POSITION IS 42 <br /> GRAPHICAL ONLY, ACTUAL POSITION PER RAISED ISLAND SEE STRUCTURAL w o <br /> EXPLOSION PROOF ON VAPOR PUMP ALIGNMENT AND BEST 100 � NIGH V � � <br /> 17 18 MANUFACTURER RECOMENDATIONS TYP. (S-1) FOR REBAR SPEC j m Q> Q <br /> ELECTRICAL J-BOX I CONNECTION. (TYP.) M x W LOW N <br /> EXPLOSION PROOF ELECTRICAL {'. i i �OPW 10BHMP-5830 DOUBLE 1/2" WIDE X 1" DEPTH BLOCK OUT _ rn <br /> 87 POPPET SHEAR VALVE FILL WITH PETROLEUM RESISTANT PTi o 0 0 0 o w CONCRETE SLAB ro of 0 <br /> SEAL-OFF (TYP.) a N N n <br /> 2-WAY CALIBRATION (TYP. OF 2) PER SUMP. TWIN TUBE SEALANT CONTINUOUS (2) CONDUIT <br /> ALONG FUEL ISLAND. (TYPICAL) <br /> r PENETRATIONS INTO <br /> VALVE o 0 0 0 1-1/2"x18" MALE X MALE VAPOR 4-5/8" 9 BOTTOM OF FRAME <br /> III <br /> 1/4" COPPER TUBING 101 SWIVEL FLEX CONNECTOR (TYP.) COUPLING (TYP BOTH SIDES) <br /> AND FITTINGS 1-1/2"08" MALE X MALE (1) 1" CONDUIT FOR DISPENSER "SIDE 1 <br /> 101 <br /> ROUTE CONDUIT UP THE SIDE SWIVEL FLEX CONNECTOR (TYP.) POWER/COMMUNICATION t7 SMITH FIBERCAST 2"02" <br /> OF DISPENSER CONTAINMENT (TYP.) _ <br /> SUMP AND THROUGH FRAME v NIPPLE TYP. INLETS DISPENSER MODEL <br /> g2 3" DW FRP BONDED 2"x1-1/2" FEMALE NPT W & X 2 GRADE SINGLE HOSE <br /> PENETRATION FITTING REDUCER BUSHING (TYP.) 75 <br /> - --- <br /> (FACTORY INSTALLED TYP.) " 55 61 SMITH FIBERCAST 3" OVER NOTE: W C- <br /> 2" 90' ELBOW PRIMARY' 57 2" FRP PIPING (TYP.) CONTRACTOR IS RESPONSIBLE FOR CORRECT ORIENTATION OF co <br /> 3' DW FRP BONDED THE S7U8-UP'S TO THE <br /> NOTE: (TYP.)' DISPENSER. ANY ADJUSTMENTS OF THE INTERNAL WORKINGS OF THE DISPENSER TO <br /> (1) 1" CONDUIT FOR DISPENSER INSTALL DISPENSER IN ACCORDANCE WITH NON-DISCRIMINATING SUMP SENSOR ACCOMMODATE INCORRECTLY INSTALLED PIPING WILL BE AT CONTRACTORS OWN EXPENSE. <br /> 52 PENETRATION FITTING '�• <br /> POWER/COMM., (1) 1" FUTURE 17 18 VR PREM. UNLD. MANUFACTURERS INSTRUCTIONS. MOUNTED FLUSH TO BOTTOM (TYP.) 9$ (FACTORY INSTALLED TYP.) STUB-UPS FROM HEADERS MUST MATCH LOCATION SHOWN IN THIS PLAN TO MATCH <br /> FIBER OPTIC & (1) 3/4" DISPENSER'S INTERNAL CONFIGURATION. pC I S <br /> NOTE: 95 DOUBLE WALL FRP (CONDUITLESS) OD •• <br /> MONITORING LIQUID SENSORS. NOTE: <br /> VAPOR PRESURE SENSOR, 2-WAY CALIBRATION NOTE: DISPENSER SUMP (TYP.) DIMENSIONS SHOWN IN THIS VIEW ARE TO BE USED FOR SIZING UNDER DISPENSER Pna <br /> DOUBLE WALL FRP (CONDUITLESS) SUMP FRONT VIEW VALVE, AND 1/4" COPPER TUBING & FITTINGS SECONDARY CONTAINMENT OF THECONTAINMENT AND CONCRETE CUTOUT CLEARANCES. g (Qj p <br /> DISPENSER SUMP (TYP.) 95 REQUIRED AT ONLY ONE (1) DISPENSER. SUMP MUST TERMINATE ABOVE SUMP SIDE VIEW <br /> BOTTOM OF DRIVE SLAB TO BE IN aTESSIQ <br /> ACCORDANCE W/ LG-162-1 (TYP.) Gilbarco Encore 500 Series H E r oNA`Fy <br /> s Sump Section Shear Valve Section Terminating Dispenser Sump Product Piping Detail MPD Dispenser Base Dimensions <br /> H 4 <br /> T-6 SCALE: 1 "=1 '-0" T-6 SCALE: 1 "=1'—O" �,T-6 NOT TO SCALE <br /> P <br /> P OF CAI-1�� ,dad <br /> SEE ARCHITECTURAL DRAWINGS SLOPE MAX . PER <br /> FOOT AX 100 FT. SAME ELEV. AS TOP <br /> EXTENDED HOSE RdRAITIRFOR DECAL DETAILS <br /> HEALY PUMP 92 93 94 OF P/V VALVE <br /> FLOAT CHECK VALVE <br /> 85 DISPENSER FRAME 91 VAC ASSIST HOSE CLAMP P/N 9468G OVERFILL 1" BLADDER SYPHON z <br /> PROTECTION VAPOR INLET ASSM. P/N <br /> VAPOR FLOW METER 103 VAPOR PRESSURE 9956 (REF. x x s ^o x <br /> 102 2"X1 REDUCER ) <br /> SENSOR BUSHING — SYPHON TUBE ADAPTER yl NI 'I C <br /> OPW 60VSPC-1001 VAPOR LINE 88 2-WAY CALIBRATION REQUIRED AT ONLY $9 3/4"x 9'-0" VAC SEE DETAIL "D" ON P/N 9939 (REF.) a o <br /> SHEAR VALVE ATTACH TO STABILIZER VALVE ONE DISPENSER ASSIST FUEL HOSE „G, e x a <br /> �. SHEET T-2 3 <br /> BAR OR STABILIZER SUPPORT. 1/4' COPPER TUBING 85 BALL VALVE P/N 996123 — <br /> BAR $ w <br /> 400 GALLON BLADDER, <br /> POSITION BASED ON VAPOR PUMP AND FITTINGS LOCK P/N 996124 xi <br /> ALIGNMENT AND BEST CONNECTION. CANOPY COLUMN (TYP.) - NEW GILBARCO NG4 "°"°° USE KEY P/N 996125 P/N 9943 (REF.) <br /> SHEAR VALVE MOUNTING MULTI-PRODUCT DISPENSER <br /> 96 SEE ARCH. PLANS (TYP.) VAPOR " <br /> BRACKET AND PLATE SINGLE HOSE EACH SIDE SYPHON TUBE <br /> 1 -1/2"x18" MALE X MALE 48"10 12" P/N 4186-6 (REF.) _ 2 <br /> SWIVEL FLEX CONNECTOR (TYP.) TOP OF ISLAND FORM PRODUCT CONFIGURATION NOTE: FOR A SINGLE HOSE PER VAC ASSIST FUEL OPEN 11 16" DIA. ' Z > y <br /> SIDE MULTI-PRODUCT DISPENSER AS SHOWN, THE ® _ 86 (RED) HOLES TAP. cu)) <br /> z n <br /> 1/2" WIDE X 1" DEPTH BLOCK REGULAR UNLEADED GRADE SELECTION BUTTON SHALL NOZZLE RED (TYP.) o w <br /> OUT FILL WITH PETROLEUM 0 0 0 0 0 0VCONCRETE SLAB ALWAYS BE LOCATED ON THE LEFT SIDE OF THE o 12" �/ AIR W a ¢ a <br /> RESISTANT PTi TWIN TUBE DISPENSER FOR BOTH SIDES. CONTRACTOR SHALL BE HELD 90 SWIVEL BREAKAWAY VALVE 24 104" REF. Z `` z W N <br /> SEALANT CONTINUOUS ALONG o 0 0 o RESPONSIBLE FOR PROPER ORIENTATION AND INSTALLATION. 45 > N N N 5 z ° <br /> FUEL ISLAND. (TYPICAL) 48" ¢ o N r- z 0 <br /> RAISED CONCRETE ° HEALY CLEAN AIR rn Ci m z <br /> TAP 1/4" COPPER TUBING REQUIRED AT 100 z w w <br /> DISPENSER CLOSEST ISLAND 14 SEPARATOR C+ ¢ , ' W <br /> INTO 1-1/2" ANVIL HEX 100 PLEASE 24" (36"� X 93° L.G.) n N N <br /> BOTTOM OF DRIVE SLAB HEAD BUSHING TO TANK FIELD ONLY CONCRETE DRIVE SLAB SEE HEALY PULL TO LO r= e <br /> INSTALL NOTE 92 93 94 T-6 " A_ P/N 9961 N W n <br /> FORWARD 30 DIA. BASE <br /> DOUBLE WALL FRP (CONDUITLESS) 95 BELOW _ PUMP _ 24, 24" �-� DRAIN <br /> NDENSATE °r `' Z <br /> Yv� UN p <br /> DISPENSER SUMP (TYP.) PLUG c <br /> PLA�VIEW TANK SLAB <br /> 2"x1-1/2" FEMALE NPT 75 55 61 2MFRPITH FIPPRNG(TYP.)OVER GRADE <br /> REDUCER BUSHING (TYP-) NOTE: G.C. TO INSTALL HEALY VAPOR VAC MOTORS. <br /> 2" 90' ELBOW "PRIMARY" 57 52 3" DW FRP BONDED PETROLEUM RESISTANT PTi TWIN TUBE SEALANT BOTTOM OF LOOP THIS INCLUDES USING A HEALY TRAINED AND CERTIFIED Q m q <br /> PENETRATION FITTING AROUND BASE OF DISPENSER AND ISLAND* TO BE 1" OFF TOP INSTALLER TO MOUNT, PIPE AND ELECTRICALLY NOTE: HEALY CLEAN AIR SEPARATOR TANK TO BE NOTE HEALY CLEAN AIR SEPARATOR = y <br /> (TYP.) LOCATED IN CONFORMANCE WITH MANUFACTURERS KIT INCLUDES CLEAN AIR SEPARATOR = a <br /> (FACTORY INSTALLED TYP.) CONTINUOUS ALONG FUEL ISLAND (TYP.) OF ISLAND (TYP.) CONNECT ALL COMPONENTS TO INSURE A COMPLETE, INSTALLATION MANUAL, CARB EXECUTIVE ORDER TANK, BALL VALVES, FLOAT CHECK, <br /> SAFE WORKING PRODUCT. FOLLOW MANUFACTURER'S AND ALL APPLICABLE STATE AND LOCAL CODES. REDUCER BUSHINGS AND ALL <br /> 2" TEE "PRIMARY" INSTALLATION INSTRUCTIONS. ACCESORIES SHOWN EXCEPT 1" PIPING. b8 000 <br /> SUMP SIDE VIEW 59 (TYP-) NOTE: ADDITIONAL SCREEN WALL OR CONSTRUCTION <br /> MAY BE REQUIRED BY LOCAL ORDINANCES. MINIMUM E <br /> MOUNTING REQUIREMENTS ARE SHOWN IN THIS o. <br /> Gilbarco Encore 500 Series DETAIL. <br /> C Sump Vapor Recovery Installation Detail MPD Electronic Dispenser u Healy Clean Air Separator Detail x m <br /> T-6 SCALE: 1 "=1 '-0" T-6 NOT TO SCALE T N ~ n <br /> 4. <br />