My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
INSTALL_2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 10:58:43 AM
Creation date
11/4/2018 2:50:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2008
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DANIELS\2440\PR0527629\INSTALL 2008.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
397
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />Note: Enhanced Leak Detection (ELD) must be performed prior to the finalins ection. <br />A separate permit application is required to install ED. <br />2. TO BE SUBMITTED PRIOR TO THE FINAL INSPECTION.• <br />❑ Complete to scale As -Built Plans <br />❑ Complete Monitoring and Response Plan <br />0 UPCF Underground Storage Tanks - InstaIlation Certificate of Compliance (one form <br />per tank) <br />❑ Completed Underground Storage Tank Certification of Financial Responsibility form <br />along with any required attachments <br />❑ Passing Line Leak Detector Test Results <br />❑ Passing Line Tightness Test Results (Required if the UST system does not satisfy the <br />California Code of Regulations 2636(8) for automatic pump shut-off.) <br />❑ Passing Enhanced Leak Detection Results <br />D. INSPECTIONS: <br />Note; A representative from the San Joaquin County Environmental Health Department <br />must witness all activities described below. <br />❑ Tank holiday test (for fiberglass -coated steel tanks) performed prior to installation in <br />excavation <br />❑ Inspection of tank vacuum gauge (if applicable) prior to placement in excavation <br />❑ Tank soap test (for fiberglass tanks) performed prior to installation in excavation <br />❑ Verification of tank set and anchorage in excavation <br />❑ Primary piping including product piping, vapor recovery and vent line piping soap and <br />pressure test <br />❑ Secondary piping including product piping, vapor recovery and vent line piping soap <br />and pressure test <br />❑ 24 -Hour secondary containment lake test on sumps and under -dispenser containment <br />❑ Visual inspection of piping to ensure proper slope prior to covering <br />❑ Overfill performance test <br />❑ Prior to receiving fuel, a complete functional test of tank and piping monitoring <br />system(s) including overfill prevention <br />Final inspection and demonstration of automatic shut down (if applicable),. <br />Revised 813107 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.