Piping information continued - <br />Check <br />Code <br />Section <br />Box <br />Code <br />Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br />Section <br />Manufacturer Madel <br />HSC <br />5290.1(c)(1) <br />Piping compatible with material intended to be stored. <br />25290.2(c)(1) <br />Choose One of the following methods: <br />❑ <br />23 CCR <br />Design and construction of piping approved by independent testing organization (e.g. UL). <br />12631(b) <br />triggering an audible visual alarm <br />❑ <br />Piping, including vent lines, sloped toward tanks with minimum 114 inch sloe per 1 foot of run. <br />❑ <br />HSC <br />restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an audible <br />❑ <br />25290.1(k) <br />alarm at least five minutes before the tank overfills <br />❑ <br />_sz90.2«&0) <br />Vapor recove , fill riser, and vent line piping are secondarily contained. <br />G. OVERSPILL/ OVERFILL PREVENTION: <br />Check <br />Bos <br />Code <br />Section <br />❑ <br />23 CCR <br />Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br />2635(b) <br />Manufacturer Madel <br />Approved overfill prevention device provided at each tank fill location. <br />Choose One of the following methods: <br />❑ <br />23 CCR <br />2636(b) <br />Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br />triggering an audible visual alarm <br />1 Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br />❑ <br />z3 CCR <br />2635(a)(2) <br />restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an audible <br />❑ <br />23 CCR <br />alarm at least five minutes before the tank overfills <br />❑ <br />2635(bX2) <br />Tie -downs, when used, constructed of non -corrosive material or coated steel. <br />Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br />capacity. <br />I Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br />tank are exposed to product due to overfilling. <br />Manufacturer Model <br />H. CORROSION PROTECTION: <br />Check <br />Box <br />Code <br />Section <br />Fiberglass reinforced plastic (FRF) <br />Piping corrosion protection: Steel with cathodic protection or impressed current <br />❑ <br />23 CCR <br />2636(b) <br />Steel isolated from contact with backfill <br />FRP or equivalent non-metallic exterior coatings or coverings <br />Tank corrosion protection: _ Sacrificial Anode <br />❑ <br />z3 CCR <br />2635(a)(2) <br />❑ Steel tank with field installed cathodic protection or impressed <br />I3 P <br />current <br />❑ <br />Tie -downs, when used, constructed of non -corrosive material or coated steel. <br />Revised 8/3/47 <br />