Laserfiche WebLink
ISD Pressure Sensor Installation Installation Steps <br />1 2.Seal wire nuts in epoxy sealant following the instructions in Figure 3. <br />,CAUTION: Epoxy sealant is irritating to eyes, respiratory system, and skin. Can cause allergic skin reaction. <br />Contains: epoxy resin and cycloaliphatic epoxycarboxylate. Precautions: Wear suitable protective clothing, <br />gloves, eye, and face protection. Use only in well ventilated areas. Wash thoroughly before eating, drinking, or <br />smoking. <br />Instructions: <br />NOTE: When temperature is below 507 (10°C), keep resin in <br />a warm place prior to mixing (e.g., in an inside pocket next <br />to body). <br />1. Open epoxy sealant package, and remove resin pak. <br />2. Holding resin pak as shown in A, bend pak along long <br />length. <br />3. As shown in B, firmly squeeze the RED SIDE of the resin, <br />forcing it through the center seal and into BLACK SIDE. <br />CFrom probe, <br />sensor, or <br />transducer To console <br />Make sure that <br />the ends of cable.. <br />sheathing are sub -r <br />merged in sealantTie wrap <br />:f <br />Wire nuts <br />4, Mix thoroughly to a uniform color by squeezing contents <br />back and forth 25-30 times. <br />5. Squeeze mixed, warm resin into one end of bag and cutoff <br />other end. <br />6. Slowly insert wiring connections into seating pack until they <br />fit snugly against the opposite end as shown in C. <br />7. Twist open end of bag and use tie wrap to close it oft and <br />position the tie wrapped end up until the resin jells. <br />Figure 3. Epoxy sealing field wiring <br />13.Push the epoxy sealed bag into the junction box. Replace and tighten the junction box cover. <br />14.Terminate field wiring into TLS Console and connect to Smart Sensor Interface Module located in the <br />intrinsically safe wiring compartment of the TLS as shown in Figure 4. Note: observe polarityl The cable length <br />between the console and sensor must not exceed 1000 feet. <br />Note: Intrinsically safe devices must be installed in accordance with Article 504 of the National Electrical <br />Code, ANSI/NFPA 70, for installation in the United States, or Section 18 of the Canadian Electrical Code for <br />installations in Canada. <br />This intrinsically safe pressure sensor PIN 331946-001, has only been evaluated for connection to a UL list- <br />ed TLS -350 Series Liquid Level Gauge f Leak Detector. <br />Conductors of different intrinsically safe circuits run in the same cable/conduit must have at least 0.01 inch <br />(0.25 mm) of insulation. <br />15.After all other ISD Vapor Flow Meters and the ISD Pressure Sensor are installed, pressurize the tank ullage <br />space and vapor piping to at least 2 inches WC and test for leaks using leak detection solution. <br />16.Replace lower dispenser sheet metal doors onto dispensers. <br />