Laserfiche WebLink
STATE OF CALIFORNI/' WATER RESOURCES CONTROr--QARD <br /> FORM 'B': UNDEMROUND STORAGE TANK PROGRAM =mom <br /> TANK TANK PERMIT APPLICATION INFORMATION ° <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. Z <br /> 10 <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWALPERMIT ❑ 5 CHANGE OF INFORMATION 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM F-12 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE 6 TANK REMOVED O W <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: �601 [)Iqrncywl st sjvek-fo'P4 FARM TANK-YES❑ NO W <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY OD <br /> A. OWNERS TANK IDN B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS'. /9,0008 <br /> 11. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ull PETROLEUM B. C. ❑ 1 UNLEADED ❑2 LEADED ❑3 DIESEL <br /> F-13 CHEMICAL PRODUCT 4 OIL ❑ 1 DUCT ❑4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑60 EMPTY ❑95 UNKNOWN 2 WASTE ❑7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.W <br /> III. TANK CONSTRUCTION MARKONE ITEM ONLY INBOXA,B,C,&D <br /> A.TYPE OF ❑ I DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTEROR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ ISTEEL/IRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 STEEL CUD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑7 ALUMINUM ❑6100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR ❑ 1 RUBBER LINED ❑2 ALKYD LINING ❑3 EPDXY LINING ❑4 PHENOUCLINING <br /> LINING ❑ 5 GLASSUNING ❑6 UNLINED ❑ 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH IOD%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> 0. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2TAR OR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U B CONCRETE A U 7 STEELCLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P 8 91 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> (LALLOIM <br /> SUBSTANCE REMAINING IN INERT MATERIALS DYES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY N JURISDICTION N AGENCY# FACILITY ID# TANK ID N <br /> / 0 7 I 1 1 3 <br /> CURRENT LOCAL AGENCY FACILITY IDN APPROVED BY NAME PHONE N WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CH CK N PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT N BY: <br /> FORM B(6-29-681 THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORM'A' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />