My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
508
>
2300 - Underground Storage Tank Program
>
PR0231057
>
COMPLIANCE INFO 2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:12 PM
Creation date
11/4/2018 3:09:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231057
PE
2361
FACILITY_ID
FA0003720
FACILITY_NAME
CHARTER WAY PETRO INC.
STREET_NUMBER
508
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16504016
CURRENT_STATUS
01
SITE_LOCATION
508 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DR MARTIN LUTHER KING JR\508\PR0231057\COMPLIANCE INFO 2007-2012.PDF
QuestysFileName
COMPLIANCE INFO 2007-2012
QuestysRecordDate
2/15/2018 12:34:40 AM
QuestysRecordID
3795241
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Nov 23 09 10:54a Reliable Petroleum: 209-845-8953 p.6 <br /> • <br /> SWRC$,January 2006 <br /> Spill Bucket Testing Report Form <br /> This form is intended for use by contractors perfonning annual testing of UST spill conlainment structures. The completed form and <br /> printoutsfrom tests(if applicable), should be provided to the facility owner,%perata forsubmittal to the local regulatory agency- <br /> 1. <br /> gency1. FACILITY INFORMATION <br /> FFacffitv <br /> ame: CHARTER WAY CHEVRON Dare of Testis <br /> ddress: 508 W. Charter Way, Stockton CA 95206 g' 10-22-09 <br /> ntact: Surinder Singh SainiPhone: 209-465-3440 <br /> Agency Was Notified of resting: 10-01-09 <br /> Name of Local Agency Inspector(lfpresent during testing): Ray Von Flue <br /> 2. TESTING CONTRACTOR INFORMATION <br /> Company Name: Reliable Petroleum Services Inc. <br /> Technician Conducting Test: Robert Barnhart <br /> Credentials': X CSLB Contractor X ICC Service Tech, n S WRCB Tark Tester ❑Other(Sped) <br /> LicenseNumber(s): 883706 5252540.UT <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: X Hydrostatic ❑Vacuum ❑Othct. <br /> Test Equipment Used: Standard Tape Measure <br /> Equipment Resolution:— <br /> Identify Spill Bucket(By Tank Tl:87 Fill T2: 91 Fill <br /> Number,Stored Product, etc.) T3: Diesel Fill <br /> Bucket Installation Type: X Direct Bury X Direct Bury X Direct Bury <br /> C Contained ' Sum ❑Direct Bury <br /> Bucket Diameter. G Contained in S G Contained in Sum ❑Contained in Sum <br /> 12 16" 12„ <br /> Bucket Depth: <br /> W. <br /> Wait time between applying 12 Y2" <br /> vacuum/water and start of test. 2mi°• 2min. 2min <br /> Test Start Time(Tl): <br /> Initial Reading W: 9:21a.m <br /> 12 /. <br /> 9:193.m 9:18a.m <br /> , „ 11 <br /> Test End Time(Tr): 10:313.m <br /> 10:29a.m 10:28a.m <br /> Final Reading(RF): 121/11 10 Y." <br /> Test Duration T T I I <br /> ( r— il� lhr. lOmin. ]hr. 10 min. <br /> Change in Read' 1hr. Ionun. <br /> °18(Rr-Rt). 0 1 inch <br /> Pass/Fail Threshold or 0 <br /> Criteria: 1/16" 1116" 1/16" <br /> Test Result: X Pass ❑ Fait <br /> ❑ Pass X Fail X Pass G Fail ❑ Pass ❑Faii <br /> Comments—(include information on repairs made riot la testis and recommendedfoliow-u orfailed tests) <br /> T2: 91 Fill SHill Bucket failed test Have already scheduled in <br /> Yon F1ii f rBucket rei2faceinnent. snectl W with Ray <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> Flrereby ceR that all the information contained in this report Is true,accurate,and in full conrpllance with legal requirements <br /> Tccbnicia,Ys Signature:_ �t -h-- <br /> 11 l.t Date: 10-22-09 <br /> State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br /> may be more stringent. <br />
The URL can be used to link to this page