My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
508
>
2300 - Underground Storage Tank Program
>
PR0231057
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/4/2018 3:15:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0231057
PE
2361
FACILITY_ID
FA0003720
FACILITY_NAME
CHARTER WAY PETRO INC.
STREET_NUMBER
508
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16504016
CURRENT_STATUS
01
SITE_LOCATION
508 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DR MARTIN LUTHER KING JR\508\PR0231057\COMPLIANCE INFO 2013-2015.PDF
QuestysFileName
COMPLIANCE INFO 2013-2015
QuestysRecordDate
2/15/2018 7:45:41 PM
QuestysRecordID
3796185
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
140
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County 40 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON #9202 508 W DR MARTIN LUTHER KING JR BLVD, aober 23 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS It,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> The Letter From Chief Financial Officer submitted to the EHD is not current The submittal of this letter in CERS is <br /> dated Novmber 4, 2013. Current financial responsibility documents are required to be submitted annually. <br /> Immediately log into the California Environmental Reporting System(CERS) at http://cers.calepa.ca.gov/, and upload <br /> the required documents. Financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. Immediately log into the California Environmental <br /> Reporting System (CERS)at http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The Site Plan indicates that there is a diesel UST on site <br /> which is incorrect. The diesel UST was converted to an 87 UST. A site plan must be submitted identifying the <br /> locations where monitoring will be performed. Immediately log into the California Environmental Reporting System <br /> (CERS) at http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. An accurate UST Monitoring <br /> Site Plan was not submitted. A site plan must be submitted identifying the locations where monitoring will be <br /> performed. Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ <br /> and upload a copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> 123 CCR 2661 Permit to repair UST system not obtained. <br /> The mechanical flapper for the 87A(south) UST was replaced on July 23, 2015. An approval letter for the repair permit <br /> was issued by EHD on August 17, 2015. The approval letter required that the inspection for the overfill prevention <br /> verification be scheduled within five days of permit approval and stated that the facility cannot receive fuel in the tank <br /> prior to the EHD inspection and approval. The facility has not ceased fuel deliveries into the 87 tank. The overfill <br /> prevention verification inspection was conducted today (10/23/15), two months past due. The All conditions included <br /> on the UST repair approval letters issued by EHD shall be followed at all times. Ensure that all conditions from UST <br /> repair approval letters in the future are followed and all inspections are performed within the required time frames. <br /> This is a Class II violation. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. The maintenance record for the <br /> installation of the 87 UST flapper completed on July 23, 2015,was not found at the facility. These records shall be <br /> maintained on site for at least three years. Monitoring records include: (1) date and time of all monitoring or sampling; <br /> (2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) results of <br /> sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring equipment, <br /> ground water elevations, or other test results; (6) results of inventory readings and reconciliations. This was corrected <br /> during the inspection when the service technician from Elite IV provided the maintenance record to the facility. <br /> This is a minor violation. <br /> Received by Inspector: n Phone: Date: <br /> (initial): STACY RIVERA, Senior REHS (209) 468-3440 10/23/2015 <br /> Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.