San Joaquin County 40 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-5232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SQH Fel^1D u: Gf+S 749 E DR MARTIN LUTHER KING JR BLVD, May 22, 2014 <br /> UST System Observations <br /> 328 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V n R ❑COS <br /> 329 CCR 2631.1 UST system not compatible with the substance stored o V u R u COS <br /> 330 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R n COS <br /> 331 HSC 25298(c) Failed to comply with permanent closure requirements n V u R D COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed u V ❑R ,:i COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R u COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V u R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation n V u R n COS <br /> 2030 See below Unlisted Operations/Maimenance violation o V n R ❑COS <br /> 2060 See below Unlisted Design/Construction violation DV u R n COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 122 Permit to repair UST system not obtained. Maintenance records on site indicate a cold start of the monitoring panel was <br /> performed on March 30, 2014 and a permit was not obtained from the EHD. Emergency repairs relating to UST system <br /> monitoring and release detection may be performed by a properly licensed, trained, and certified contractor pursuant to <br /> the EHD'S policy and a permit obtained within one business day from the EHD. All other repairs must have a permit <br /> submitted to and approved by the EHD prior to beginning work. Immediately obtain a permit from the EHD for the <br /> monitoring panel cold start. A"Failure to Obtain a Permit" penalty applies. This is a Class II violation. <br /> 204 Current monitoring plan approved by the EHD not found on site. An approved copy of the monitoring plans were not <br /> found on site. A copy of these plans shall be retained on site at all times. Immediately locate and retain a copy on site. <br /> This is a repeat violation, Class II. <br /> 206 Designated operator did not inspect all required items and/or the inspection reports not completed. The designated <br /> operator failed to check and note the correct test dates for the secondary containment testing on the July through <br /> December 2013 and the January through April 2014 designated operator monthly inspection report. Secondary <br /> containment testing was last conducted on March 19, 2012. During the monthly inspection, the designated operator <br /> shall check that all required testing and maintenance for the UST system have been completed and document the dates <br /> they were done. Ensure that designated operators performing monthly inspections at this facility are including all of the <br /> required information on the reports. This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by June 22, 2014. <br /> Consent to perform the inspection, take photos and collect samples was given by the owner, Muhammad <br /> (Johnny) Rizwan. This facility's designated operator is Dan Mcllrath (ICC expiration date: 5/31/14) . The service <br /> technician was David Winkler (ICC expiration date: 3/3/16), who had the following manufacturer's certifications: <br /> Veeder-Root Level 4 (expiration date: 2/10/16) VMI Tester (expiration date: 11/10/15). <br /> Note: Facility operators are required to upload the following UST program documents into the California <br /> eceived pnrtra Inspector: one: ate: <br /> STACY RIVERA, Senior REHS (209)468-3440 05!22,2014 <br /> Page 3 of 4 <br />