Laserfiche WebLink
AUTO SENSOR WATER ALARM <br /> SYSTEM SECURITY DISABLED <br /> •CODE : 000000 • AUTO SENSOR OUT ALARM <br /> DISABLED <br /> MAINTENANCE HISTORY <br /> DISABLED <br /> US GAS I TANK CHART SECURITY <br /> DISABLED <br /> CUSTOM ALARMS RS-232 END OF MESSAGE <br /> MAY 2, 2012 9:09 AM DISABLED DISABLED <br /> SERVICE NOTICE <br /> SYSTEM STATUS REPORT DISABLED <br /> T 2:DELIVERY NEEDED ISO 3166 COUNTRY <br /> T 3:DELIVERY NEEDED ! CODE: <br /> VAPOR MONITORING TYPE <br /> CARB ISD IN-TANK SETUP <br /> MASS/DENSITY <br /> DISABLED T 1 :87 <br /> PRODUCT CODE 1 <br /> THERMAL COEFF : .000700 <br /> TANK DIAMETER 96.00 <br /> TANK PROFILE 1 PT <br /> SYSTEM SETUP FULL VOL 11993 <br /> MAY 2, 2012 9:10 AM FLOAT SIZE: 4.0 IN. <br /> WATER WARNING 2.0 <br /> SYSTEM UNITS HIGH WATER LIMIT: 3.0 <br /> U.S. WATER ALARM FILTER: HIGH <br /> SYSTEM IA"NGUAGE COMMUNICATIONS SETUP <br /> ENGLISH - - - - - - - - MAX FI LABEL VOL: 11993 <br /> SYSTEM DATE. 11.11: FORMAT OVERLIMIT 903 <br /> 10793 <br /> MON DD YYYY HH:MM:SS XM <br /> ' PORT SETTINGS: HIGH PRODUCT 11393 <br /> US GAS COMM BOARD : 1 (EDIM ) DELIVERY LIMIT 123 <br /> RS-232 SECURITY 1440 <br /> CODE : DISABLED <br /> LOW PRODUCT 300 <br /> SHIFT TIME 1 : DISABLED COMM BOARD : 5 (RS-485) LEAK ALARM LIMIT: 99 <br /> BAUD RATE : ^2400 SUDDEN LOSS LIMIT: 99 <br /> SHIFT TIME 2 : DISABLED <br /> SHIFT TIME 3 : DISABLED i PARITY EVEN TANK TILT 1 .20 <br /> SHIFT TIME 4 : DISABLED STOP BIT : I STOP PROBE OFFSET 0.00 <br /> DATA LENGTH: 7 DATA <br /> TANK PER TST NEEDED WRN RS-232 SECURITY <br /> DISABLED CODE : DISABLED SIPHON MANIFOLDED TANKS <br /> TANK ANN TST NEEDED WRN NONE <br /> DISABLED COMM HOARD 6 (RS-232) LI LINE MANIFQLDED TANKS <br /> BAUD RATE : 1200 Trt: NONE <br /> LINE RE-ENABLE METHOD PARITY ODD <br /> PASS LINE TEST STOP BIT I STOP <br /> DATA LENGTH: 7 DATA LEAK MIN PERIODIC: 00 <br /> LINE PER TST NEEDED WRN RS-232 SECURITY <br /> DISABLED CODE : DISABLED <br /> LINE ANN TST NEEDED WRN LEAK MIN ANNUAL 03 <br /> ? <br /> 0 <br /> DISABLED AUTO TRANSMIT SETTINGS: <br /> PRINT TC VOLUMES AUTO LEAK ALARM LIMIT PERIODIC TEST TYPE <br /> ENABLED ( DISABLED STANDARD <br /> TEMP COMPENSATION AUTO HIGH WATER LIMIT ANNUAL TEST FAIL <br /> VALUE (DEG F ) : 60.0 DISABLED <br /> STICK HEIGHT OFFSET AUTO OVERFILL LIMIT ALARM DISABLED <br /> DISABLED DISABLED <br /> ULLAGE: 90% AUTO LOW PRODUCT PERIODIC TEST FAIL <br /> DISABLED ALARM DISABLED <br /> H-PROTOCOL DATA FORMAT AUTO THEFT LIMIT <br /> HEIGHT DISABLED GROSS TEST FAIL <br /> DAYLIGHT SAVING TIME AUTO DELIVERY START ALARM DISABLED <br /> DISABLED <br /> ED <br /> RE-DIRECT LOCAL PRINTOUT AUTO DELIVERY END ANN TEST AVERAGING: OFF <br /> DISABLED DISABLED PER TEST AVERAGING: OFF <br /> AUTO EXTERNAL INPUT ON <br /> EURO PROTOCOL PREFIX DISABLED TANK TEST NOTIFY: OFF <br /> S AUTO EXTERNAL INPUT OFF <br /> DISABLED TNK TST SIPHON BREAK:OFF <br /> AUTO SENSOR FUEL ALARM <br /> DISABLED DELIVERY DELAY 1 MIN <br /> PUMP THRESHOLD : 10.003 <br />