My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1991 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 1991 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 3:26:05 PM
Creation date
11/4/2018 3:36:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991 - 2004
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 1991 - 2004.PDF
QuestysFileName
COMPLIANCE INFO 1991 - 2004
QuestysRecordDate
4/25/2018 10:10:21 PM
QuestysRecordID
3869105
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
203
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> Tanknology <br /> 8900 SHOAL CREEK, BUILDING 200 <br /> TEST DATE: 01/16/03 AUSTIN,TEXAS 78757(512)451-6334 WORK ORDER NUMBER: 2225093 <br /> CLIENT: VERTEX SERVICES, LLC SITE: RYDER 1071A <br /> TANK INFORMATION <br /> Tank IF: 2/RESERV 2 Tank manifolded: YES Bottom to top fill in inches: 166.5 <br /> Product: DIESEL Vent manifolded: YES Bottom to grade in inches: <br /> Capacity in gallons: 6,086 Vapor recovery manifolded: NO Fill pipe length in inches: 70.5 <br /> Diameter in inches: 96.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 197 Overspill protection: YES Stage I vapor recovery: NONE <br /> Material: DN STEEL Installed: ATG Stage II vapor recovery: NONE <br /> CP installed on: <br /> COMMENTS <br /> Note that line "A" refers to the RESERVE DIESEL Main line, line "B" refers to sat 3, line "C" refers <br /> to sat 4, NOTE that line "D" refers to sat 6 (this is supplied by the Main Diesel system) . <br /> TANK TEST RESULTS a Test Method: NONE LEAK DETECTOR TEST RESULTS Test method: <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.k1 L.D.#1 L.D.42 L.D.#2 <br /> UFT/OFT: Make: VAPORLESS RED JACKET <br /> Fluid volume in gallons: Model: LD2000 FX2-DV <br /> Tank water level in inches: S/N: 02081011 10299-7997 <br /> Test time: NOT Open time in sec: 2.00 <br /> Number of thermisters: TESTED Holding psi: 30 NOT <br /> Specific gravity: Resiliency in ml: 90 TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by (method): Metering psi: 18 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS FAIL <br /> COMMENTS COMMENTS <br /> �'hC $ tlp } <br /> 11I.LAGE TF„ T R `N �+ t� +1i �i 'I Sr,' '' `" "G I ,I,i'S�,ak741„+ `,'+r.��lS°I I .._ <br /> Pry,R. i.�.. .rn .# .,....,F.i1. r ..A�' , .... ... ..: ,..... <br /> Test time: <br /> Ullage volume: Material: DW FIBERG FIBERGLASS FIBERGLASS FIBERGLASS <br /> Ullage pressure: Diameter(in): 2.0 2.0 2.0 2.0 <br /> Results: Length (ft): 100.0 25.0 25.0 25.0 <br /> Test psi: 50 50 50 <br /> DATA FOR UTS-4T ONLY: Bleedback cc: 0 0 0 <br /> Time of test 1: Test time(min): 40 40 40 <br /> Temperature: NOT Start time: 15:17 15:17 15:17 NOT <br /> Flow rate (cfh): TESTED End time: 15:57 15:57 15:57 TESTED <br /> Time of test 2: Final gph: -0.003 -0.003 -0.003 <br /> Temperature: Result: PASS PASS PASS <br /> Flow rate (cfh): Pump type: PRESSURE PRESSURE PRESSURE PRESSURE <br /> Time of test 3: Pump make: RED JACKET NONE NONE NONE <br /> Temperature: <br /> Flow rate (cfh): Impact Valves Operational: YES <br /> COMMENTS COMMENTS <br /> Printed 02/12/2003 08:40 MSHAW <br />