My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 2004 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:07 PM
Creation date
11/4/2018 3:40:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2006
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 2004 - 2006.PDF
QuestysFileName
COMPLIANCE INFO 2004 - 2006
QuestysRecordDate
4/25/2018 10:46:56 PM
QuestysRecordID
3869444
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
155
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />0 <br />INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />J'iv Tanknology <br />TEST DATE: 06/20/05 8501 N MOPAC EXPRESSWAY, SUITE 400 <br />AUSTIN, TEXAS 78759 (512) 451-6334 WORK ORDER NUMBER: 2235956 <br />CLIENT; RYDER FUEL COMPLIANCE SITE: RYDER 1071A <br />Tank ID: 12K <br />Product: DIESEL <br />Capacity in gallons: 12,110 <br />Diameter in inches: 96.00 <br />Length in inches: 391 <br />Material: DW STEEL <br />TANK INFORMATIC <br />1 Tank manifolded: No <br />Vent manifolded: YES <br />Vapor recovery manifolded: No <br />Overfill protection: YES <br />Overspill protection: YES <br />Installed: ATG <br />CP installed on: / / <br />Bottom to top fill in inches: 168.8 <br />Bottom to grade in inches: <br />Fill pipe length in inches: 72.8 <br />Fill pipe diameter in inches: 4.0 <br />Stage I vapor recovery: NONE <br />Stage If vapor recovery: NONE <br />COMMENTS <br />Note that Zine "A" refers to the Main supply line dispenser# 3-4, line "B" refers to satelite <br />dispenser#3, line "c" refers to satelite dispenser# 4. <br />Printed 06/23/2005 12:29 KOHLMEYER <br />1--.n um,rc',J WM I Co E KLbUL1 5 1- TeSt! method; <br />PSI at tank bottom. <br />Fluid level in inches: <br />Newlpassed Failed/replaced New/passed Failed/replaced <br />L.D. #1 <br />L.D. #1 L.D. #2 L.D. #2 <br />UFT/OFT: <br />Fluid volume in gallons: <br />Make: <br />Tank water level in inches: <br />Model: <br />Test time: <br />S1N: <br />Number of thermisters: NOT <br />Open time in sec: <br />Specific gravity: TESTED <br />Holding psi: <br />NOT NOT <br />Water table depth in inches: <br />Resiliency cc: <br />TESTED TESTED <br />Determined by (method): <br />est leak rate ml/m: <br />Leak rate in gph: <br />Metering psi:Calib. <br />leak in gph: <br />Result: <br />Results: <br />COMMENTS <br />COMMENTS <br />ULLAGE TEST RESULTS Test Method: NONE <br />LINE TEST RESULTS <br />Test type: TLR-I <br />Test time: <br />Ullage volume: <br />Material: DW FIBERG <br />DW FIBERG DW FIBERG FIBERGLASS <br />Ullage pressure: <br />Diameter (in): 2.0 <br />2.0 2.0 <br />Results: <br />Length (ft): 100.0 <br />25.0 25.0 <br />Test psi: 50 <br />50 50 <br />DATA FOR UTS-4T ONLY: <br />Bieedback cc. 0 <br />0 0 <br />Time of test 1: <br />Test time (min): 30 <br />30 30 <br />Temperature: NOT <br />Start time: 08: 50 <br />08:50 08:50 NOT <br />Flow rate (cfh): TESTED <br />End time: 09:20 <br />09:20 09:20 TESTED <br />Time of test 2: <br />Final gph: 0.000 <br />0.000 0.000 <br />Temperature: <br />Result: PASS <br />PASS PASS <br />Flow rate (cfh): <br />Pump type: PRESSURE <br />PRESSURE PRESSURE NONE <br />Time of test 3: <br />Pump make: RED JACKET <br />NONE NONE NONE <br />Temperature: <br />Flow rate (cfh): <br />Impact Valves Operational: YES <br />COMMENTS <br />COMMENTS <br />NOTE MAIN LINE AND SATELLITE LINES TESTED AS ONE.LINE A= MAIN LINE <br />DISPENSER# 3-4 LINE B= SATELLITE DISPENSER#3 LINE C= SATELLITE <br />DISPENSER#4 <br />Printed 06/23/2005 12:29 KOHLMEYER <br />