My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 3:03:36 PM
Creation date
11/4/2018 3:52:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\BILLING 2015.PDF
QuestysFileName
BILLING 2015
QuestysRecordDate
4/26/2018 7:57:02 PM
QuestysRecordID
3871781
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Alk <br /> IFIED PROGRAM CONSOLIDATED FOk,.r <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-(Page 1 of 2) <br /> TYPE OF ACTION ❑ I.NEW PLAN (1 2.CHANGE OF INFORMATION <br /> _9x1. <br /> PLAN TYPE ❑ I.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. <br /> (Check one item on( 49-32. <br /> y) ® 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): 2 K Used Oil <br /> FACILITY ID It(Agency Use Onlv) I FACILITY INFORMATION <br /> BUSINESS NAME(Same as Facility Name or DBA) <br /> Ryder Transportation Services#1071 3. <br /> BUSINESS SITE ADDRESS <br /> 3633 Duck Creek Dr. 03. CITY IN <br /> Stockton <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibmli0n of monitoring equipment(e.g.,sensors,probes, line leak detectors,etc.)mus[be performed a[the frequency specified <br /> bathe equipment manufacturers'instructions,or annually,whichever is more <br /> frequent.Such work must be erformed b uaQled ersonnel. 23_cca 263_2 263_4,z6Js zeal <br /> MONITORINGEQUIPMENT IS SERVICED -A----"Y S'--- _ _L_ g 1 <br /> LR 1.ANNUALLY <br /> ❑ 99.OTHER(Specify): 490-�o-.. <br /> IIL MONITORING LOCATIONS 490,b. <br /> ❑ I NEW SITE..PLOT PLAN/MAP SUBMITTED WITH THIS PLAN [A 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED4904. <br /> ix3 CCR§2632 x63_4] <br /> IV- TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (CheckallI.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACES)OR SECONDARY CONTAINMENT VAULTS) 490-5. <br /> WITH AUDIBLE AND VISUAL ALARMS[7.3 cca§2632.26341 <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY ® b.LIQUID FILLED ❑ c.PRESSURIZED ❑ J.UNDER VACUUM 490-6. <br /> PANEL MANUFACTURER: Wader Root 490.7. TLS-350 490-9. <br /> LEAK SENSOR MANUFACTURER: MODEL#: <br /> Veeder Root °90.9. MODEL#(S): 420 490.10. <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TXR_K.[23cca§26_3_1 -4071-- <br /> PANEL MANUFACTURER: 490.12. MODEL III 49a 13. <br /> IN-TANK PROBE MANUFACTURER: 490-14' MODEL#(S): 49a1s. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY90.16. <br /> ❑ c,WEEKLY 4 <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17. <br /> PROGRAMMED TESTS_ _ ❑ a_0.1 B_p_b__ ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): 490-19. <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[231§21111 490 19. <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)[z3_cca gz64s7 TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 49_21. <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 cca§2643_.11 ____ 490-zz. <br /> -2i. <br /> 490 <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BOsNNIALLY 49-32_. <br /> .............TEST Q c.OTHER(Spec-- <br /> ❑ 99.OTHER(Specify): 490.7.5_ _ <br /> 490.26. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br /> (Check alI <br /> that apply) <br /> ® 1.CONTINUOUS MONITORING OFPIPE/PIPING SUMPS)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 4Y0-29. <br /> [§M36] SECONDARY CONTAINMENT IS: ® a.DRY <br /> ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 49039. <br /> PANEL MANUFACTURER: Veeder Root _9o-J0. MODEL#: TLS - 350 490-31. <br /> LEAK SENSOR MANUFACTURER: Veeder ROOt 490_2' MODEL#(S): 205 490-33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 49 34. <br /> _ FAILURENISCONNECTION OF THE MONTCORING SYSTEM TRIGGERS AUTOMATIC PUMP <br /> HANICa <br /> SHUT .DO WN. YES b.NO 9x <br /> 435. <br /> ❑ 2.MECAL LINE LEAK DETECTOR(MELD)THAT ROUTINELY PERFORMS 3.0 ® ❑ <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 cca§2636] g.P.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF 49U-3_6. <br /> MLLD MANUFACTURER(S): 490-37. MODEL#1 a90aa. <br /> ❑ 3.ELECTRONIC LME LEAK DETECTOR(FLED)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.IzJ ccagz6J6] a____ <br /> ELLD MANUFACTURER(S): 490-__ MODEL#(S): 490.41. <br /> PROGRAMMED IN LAZE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 h. e9o-4z. <br /> g.p. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 090-43. <br /> _ ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 490'44 <br /> ❑ 4.PhE INTEGRITY TESTING. ---- 49045.. <br /> _TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHEA(Specify) 490.46. <br /> ® <br /> 5-V PIPE MONITORING. used oil sump ----- --- a9oaZ <br /> 490 49. <br /> FREQUENCY: ® a.DAILY ❑ b.WEEKLY <br /> ❑ c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED' 490-49. <br /> ❑ 6.SUCTION PANG MEETS EXEMPTION CRITERIA.[23_cca g2636(ex3)7 Allowed for monilon'ng afunburied emvpency gezretar fue�N�lyper HSC;25281.5(b)(J�_- <br /> -- 490.50. <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 2Q CHAPTER 6.715 CONNECTED TO THE TANK SYSTEM. a9a-sl <br /> ps 99.OTHER(Specify) Line is gravity-fed, not pressurized. ------ 490-s7. <br /> UPCF UST-D(12/2007)-I/6 www,unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.