My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 3:03:36 PM
Creation date
11/4/2018 3:52:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\BILLING 2015.PDF
QuestysFileName
BILLING 2015
QuestysRecordDate
4/26/2018 7:57:02 PM
QuestysRecordID
3871781
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUNDSTORAGETANK <br /> MONITORING PLAN-PAGE 2 <br /> VI.DISPENSER MONITORING <br /> MONITORING OF AREAS BENEATH DISPENSER(S)IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) MSa <br /> �] I.CONTINUOUS ELECTRONIC MONITORING OF•IU�NDDERR DISPENSER CONTAINMENT(UDC) �-/� <br /> PANEL MANUFACTURER: Veec�ErFietz+ W1. MODEL#: 2> 3SD M52 <br /> LEAK SENSORMANUFACTURER: ef' e.'( Mss MODELN(S <br /> WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? M4 YES ❑ b.NO Mss. <br /> WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? [TjI YES ❑ b.NO Ms6. <br /> WILL FAILUREIDISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMPSHUTDOWN? OR-rYES ❑ b.NO aur <br /> ❑ 2.MECHANICAL ASSEMBLY(e.g.,FLOAT AND CHAIN ASSEMBLY)IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br /> ASSEMBLY MANUFACTURER: MssMODEL N(S); Mss <br /> ❑ 3.VISUAL MONITORING DONE: ❑ a.DAILY ❑ b.WEEKLY(Rymra sjaR r vst) M81 <br /> ❑ 4.NO DISPENSERS <br /> ❑ 99.OTHER(Specify) Mel. <br /> VII. ENHANCED LEAK DETECTION <br /> ❑ 1.WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK MIO. <br /> DETECTION(ELD)FOR THE UST(S)COVERED BY THIS PLAN.PER 23 CCR§2644.1,EIA IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br /> VIII. TRAINING <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) Mm. <br /> I. ff'THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) <br /> 2. a- OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) <br /> 3. g'THE FACILITY'S BEST MANAGEMENT PRACTICES(Required as of 1/01/1005) <br /> 4. CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br /> 5. ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br /> 6. ❑ STATE WATER RESOURCES CONTROL BOARD(SWRCB)PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> 7. ❑ SWRCB PUBLICATION:"WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS- <br /> 99. OTHER(Specify) Mal <br /> Personnel with UST monitoring responsibilities aro familiar with all of the above documents relevant to their job duties and can access those documents when needed. <br /> By January 1,2005 this facility will have a"Designated UST Operator"who has passed the operator exam administered by the International Code Council(ICC). By <br /> January I,2005,and annually thereafter,the "Designated UST Operator"will nein facility employees in the proper operation and maintenance of the UST systems, <br /> This training will include,but is not limited in,the following: <br /> D Operation of the UST systems in a manner consistent with the facility's best management practices. <br /> ➢ The facility employee's role with regard to the leak detection equipment. <br /> D The facility employee's role with regard m spills and overfills. <br /> D Whom to contact for emergenciesand leak detection alarms. <br /> For facility employees hired on or after January 1,2005,the initial training will be conducted within 30 days of the date of hire. <br /> IX- COMMENTS/ADDITIONAL INFORMATION <br /> Please use this section to,include any additional UST system monimrmg-related i;rformation(ag.,additional information required by your local agency): Mas. <br /> pre V%-L\j�iLs c4 g5°ly <br /> der u e l gat e e� <br /> X. PERSONNEL RESPONSIBILITIES <br /> AS OF 1/1/05,THE"DESIGNATED UST OPERATOR" IDENTIFIED IN SECTION III OF THE CURRENT UST OPERATING PERMIT APPLICATION - <br /> FACILITY FORM WILL HAVE ULTIMATE AUTHORITY FOR PERFORMING THE MONITORING ACTIVITIES AND MAINTAINING LEAK DETECTION <br /> EQUIPMENT COVERED BY THIS PLAN,AND WILL PERFORM AND DOCUMENT MINIMUM MONTHLY VISUAL INSPECTIONS OF THE FACILITY' <br /> UST SYSTEMS IN ACCORDANCE WITH 23 CCR&2715(b). <br /> XI. OWNER/OPERATOR SIGNATURE <br /> CERTMCATIOII:I ctrfif,that the inferrnatiou provided herein is true and accurate to 0 k wl <br /> WNERlOPERATO tGVu`AT(1 BFpRFCEIlf1C(S'' 't DA t % M . <br /> 1vt <br /> 0 Operator till f -2—Q(l <br /> WNER/OP• TOR NAME(print' Msa' WNER/OPIRATOR TITLE: Msa. <br /> (Agency Usr O ) This plan has been revie and: Appmvcd ❑Approved With Conditions ❑Disapproved —11 <br /> Local Agency Signatum' z A Date: 1.12 -140 <br /> Commems/Spocial Conditions: <br /> SJCF-HD-d(07/03)-3/4 07?23/03 <br />