My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1502
>
2300 - Underground Storage Tank Program
>
PR0231082
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2020 12:24:33 PM
Creation date
11/4/2018 4:00:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231082
PE
2381
FACILITY_ID
FA0003794
FACILITY_NAME
CIRCLE K STORE #5643*
STREET_NUMBER
1502
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12708018
CURRENT_STATUS
02
SITE_LOCATION
1502 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\1502\PR0231082\COMPLIANCE INFO 1998 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 1998 - 2008
QuestysRecordDate
8/9/2017 8:52:33 PM
QuestysRecordID
72797
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CALIFORNIA MONTHLY <br />STATISTICAL INVENTORY RECONCILATION (SIR) REPORT <br />SIR-Provider`s ETL Southwest Phone (602) 837-8738 <br />SIR Version SIRAS — version 2.8.3 Date of SIR report 7/15/96 <br />Period Covered 6/96 What is the required number of usable inventory days per tank? 30 <br />Unocal No. 4409 <br />1502 N. EI Dorado <br />9 Stockton, CA 95204 <br />ACILITYN'AME " <br />Unocal No. <br />4409 <br />TANK <br />LOCATION <br />Address <br />1502 N. EI Dorado <br />City <br />Stockton <br />Phone (714) 572-7653 Zip 95204 <br />TANK OWNER - <br />Name <br />Unocal <br />Address 2929 E. Imperial Highway <br />City Brea Phone (714) 572-7653 <br />ANKOPERATOR <br />Name <br />Unocal <br />Phone <br />(714) 572-7653 <br />Tank No. 87-1 Regular Unleaded <br />12000 <br />Leak <br />Threshold <br />gph <br />0.10 <br />This Month _ <br />Minimum Calculated Pass, Fail, <br />Detectable Leak Rate (6b) Inconclusive <br />Leak Rate (so) <br />gph gph P F I <br />0.20 -0.07 * <br />Last <br />Month (7) <br />Pass, Fall, <br />Inconclusive <br />Two <br />Months <br />Ago (7) <br />Pass, Fail, <br />Inconclusive <br />P F 1 <br />P F I <br />* <br />* <br />Tank No. 92-1 Premium <br />Unleaded <br />12000 <br />0.10 <br />0.20 <br />-0.03 <br />Tank No. DSL -1 Diesel <br />12000 <br />0.10 <br />0.20 <br />-0.35 <br />NOTE: N/A indicates No Analysis Performed Negative Calculated Leak Rales indicate a Gain <br />1. The tank owner is required to have an SIR report for each month [Section 2643 (b)(3) CCR']. <br />2. Monthly reports must be submitted to the local agency upon request [Section 2712 (b) CCR]. <br />3. The tank owner is required to have the report by the 20th day of the following month [Section 2646.1 (c) CCR). <br />4. If for any reason, the test is neither "pass" nor "fail", the "inconclusive column must be marked. <br />5. The local agency must be notified of a tank that does not pass the SIR test within 24 hours of receipt of the report and the SIR report must be <br />submitted to the local agency within 10 days of the date of the report [Section 2646.1 (d) CCR). <br />6. Quantitative and Qualitative Methods: <br />a. A leak threshold, minimum detectable leak rate, and calculated leak rate must be provided for each tank. If not, then the tank failed the SIR test. <br />b. If the calculated leak rate for a tank is greater than or equal to the leak threshold, the tank failed the SIR test. <br />c. If the minimum detectable leak rate for a tank is greater than the certified performance standard (i.e., 0.1 or 0.2 gph) and the calculated leak rate <br />is less than the leak threshold, the test is inconclusive for that month. <br />d. Two consecutive failures and/or inconclusives require a tank and/or piping integrity test within 15 days from the date of the <br />second report [Section 2646.1 (h) CCR]. <br />7. Optional. <br />rt'<i Ct�»g eu�iva�r4ri, <br />Date <br />OCR means Title 23, DMsion 3, Chapter 16 of the California Code of Regulations <br />SWRCB—SIR/MON-01 (12/94) <br />