Laserfiche WebLink
'LABORATORY CONTROL SAMPLE .. <br />QUALITY CONTROL REPORT <br />Analyzed By: G. Barrett, P. Macias <br />Twining Laboratories. Inc. Examination Number: 69905581.1-2 <br />Reviewed By: F. Hoevertsz <br />Constituent <br />MB <br />Result <br />Spike <br />Level <br />LCS <br />Result <br />LCSD <br />Result <br />LCS <br />% Rec <br />LCSD <br />% Rec. <br />RPD <br />Cadmium (Cd) <br /><0.01 <br />0.04 <br />0.0408 <br />0.0410 <br />102 <br />103 <br />0.49 <br />Chromium (Cr) <br /><0.05 <br />0.2 <br />0.205 <br />0.205 <br />103 <br />103 <br />0 <br />Lead (Pb) <br /><0.05 <br />0.2 <br />0.198 <br />0.199 <br />99.0 <br />99.5 <br />0.50 <br />Nickel (Ni) <br /><0.05 <br />0.2 <br />0.200 <br />0.201 <br />100 <br />101 <br />0.50 <br />Zinc (Zn) <br /><0.05 <br />0.2 <br />0.195 <br />0.196 <br />97.5 <br />98.0 <br />0.51 <br />Hexavalent Chromium (Cr") <br /><0.01 <br />0.1 <br />0.098 <br />0.098 <br />98 <br />98 <br />0 <br />EXPLANATIONS: <br />All concentrations in mg/Kg: Milligrams per kilogram (ppm) <br />Method Blank: The method blank is used to determine if method analytes or other interferences are <br />present in the laboratory environment, the reagents or apparatus. <br />Laboratory Control Sample: A laboratory control sample is generated by spiking the analyte into a relatively inert <br />matrix (clean sand or blank water). The laboratory control sample is analyzed <br />exactly like a sample, and its purpose is to determine whether the methodology is in <br />control and whether the laboratory is capable of making accurate and precise <br />measurements. <br />Rev. 3 05197 IOC.WKSI <br />