My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
430
>
2300 - Underground Storage Tank Program
>
PR0232369
>
REMOVAL_1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:43:34 PM
Creation date
11/4/2018 4:16:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1997
RECORD_ID
PR0232369
PE
2381
FACILITY_ID
FA0003975
FACILITY_NAME
SKEETERS AUTO TRANSMISSIONS
STREET_NUMBER
430
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14906413
CURRENT_STATUS
02
SITE_LOCATION
430 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\430\PR0232369\REMOVAL 1997.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN c..,,;Y PUBLIC HEALTH SERVICES/ENVIRONMENTAL 6r DIVISION <br /> I. u+ST WORKSHEET FOR SITE CLOSURE EVALUATION DATE — 6 <br /> NAME Of FACILITY SWEEPS CODE ✓�� L <br /> ADDRESS y-3 p n, ,s f TANK ID #3C' -�3� — 0 <br /> TANK SIZE 3, 0063 FUEL TYPE JZ2 G-,.S <br /> 11. GENERAL SITE HISTORY <br /> Is permit current? Yes No Permit # - Facility Status Code Doc.Soil/GW Cont Yes No <br /> Number of Tanks at facility Age of Tanks(if available) Type of Tank Steel Fbrgl Sngl Dual <br /> 111. TANK HISTORY <br /> Was Tank tested? Yes No Failed precision test ? Yes No If yes, give date(s) <br /> Was a repair made to the tank system? Yes No If yes, what was repaired? <br /> Was repair done under inspection? Yes No Were soil samples analyzed? Yes No BTXE TPH-G TPH-D Pb/EDB <br /> Type of failure/discharge catastrophic long-term Leakage overfill unknown other: <br /> IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soil Samples Received Yes No Depth to Ground Water Ref/Year Average Annual Precipitation A= 14 .10-25 <br /> On-Site WeLI(s) Yes No Number & Type Irr Dom Pub <br /> S Score S Score S Score <br /> Distance to Well from Tank ft; ft; ft C 10 pts C 9 pts C 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R condition <br /> V. Site Feature - Leaching Potential Analysis E is met E is met E is met <br /> Minimum Depth to groundwater from the Soil Sample (feet) 30_ >100 51-100 25-50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) None Unknown Present <br /> Average Annual Precipitation (inches) xxxxxx <10 9 10-25 xxxxxxx 26-40\2 <br /> Man-Made conduits which increase vertical migration <br /> of leachate (i.e., septic systems, water wells, ponds) None Unknown Present <br /> Unique site features: Recharge area, coarse soil, nearby wells. At Least More than <br /> xxxxxx None one one <br /> �COLUMN TOTALS>>>TOTAL POINTS ' + a I-] + O = -,57 <br /> Sample Result: (B T X OR E) RANGE OF TOTAL POINTS 49 pts or more 41 - 48 pts 40 pts or less <br /> 81 X E B T X E <br /> MAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. 1. NA\3 <br /> Sample Result: GASOLINE 1000 100 70 <br /> MAXIMUM ALLOWABLE TPN LEVELS (PPM) <br /> TPH DIESEL 10,000 1000 100 <br /> FOOTNOTES: ---If documented soil and/or ground water contamination is present, do not complete the Leaching potential <br /> analysis. (i.e., site is currently on UGT Contamination List for soil or ground water.) <br /> \1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> \3 Levels for BTX&E are not applicable at a TPN concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> VI. STAFF RECOMMENDATION/CONCLUSION <br /> 1. Are BTX & E or TPH Concentrations > Allowable Levels -Yes No <br /> _ L _ <br /> 2. Recommend Site Closure Yes No If Yes, Refer to Site Mitigation for Evaluation <br /> VII. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR <br /> CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE YES NO REFERRED TO SITE MITIGATION FOR EVALUATION YES NO <br /> DATE REFERRED / / DATE CLOSURE LETTER MAILED <br /> NAME OF <br /> EVALUATOR <br /> EH 23 BO (UGTWKSHT)\5/90 <br />