My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
706
>
2300 - Underground Storage Tank Program
>
PR0500990
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2021 10:09:50 PM
Creation date
11/4/2018 4:21:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0500990
PE
2381
FACILITY_ID
FA0004958
FACILITY_NAME
CHARLIES DAY & NIGHT
STREET_NUMBER
706
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13905410
CURRENT_STATUS
02
SITE_LOCATION
706 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\706\PR0500990\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
11/28/2012 8:00:00 AM
QuestysRecordID
74697
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD 3A ' <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> I <br /> y� COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY OSED ON S E <br /> ONE ITEM 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOV <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNERS TANK 1.D.# S. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) D. TANK CAPACITY IN GALLONS: <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. EllaREGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> �2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT ❑ 1b PREMIUM UNLEADED ❑ 6 GASAHOL ❑ ] METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 8 M85 <br /> LQ 2C MIIDDGRADE UNLEADED DED 0 99J TIER(DESlFUELO IN ITEM D.BFLOVA <br /> D. IF(A7)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A S.It: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK I BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (p6nq TMk) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ i RUBBER UNED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIB WITH 100% METHANOL? YES_ NO_ <br /> D.EXTERIOR ❑ 1 POLYE 14YLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 91 NONE E::]95 UNKNOWN ❑ 99 OTHER <br /> E SPILL AND OVERFILL,MO. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES_ NO_ STRIKER PLATE YES_ NO_ DISPENSER CONTAINMENT YES NO <br /> IV.PIPING INFORMATI N CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLEPIPING A U 99 OTHER <br /> B. CONSTRUCTION A i SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U ] STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A4)95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION1 Ia:cKAMat U"tFAK 2 ME Mw W M IWERSm 4 EUMQIc UHE 5 AUM11C PULP <br /> ❑ OflEGTaR ❑ TES9Na ❑3 Can MOMTO3Rp ❑ IEYI UETECMR ❑ SHUTI m ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 RECONCILIATION MANUAL ORV ❑ 3 MONITORING ❑ 4 GAUGINAUTOMATG MONITORING <br /> TANK ❑ 5 MONTORINGGROUND �R ❑ 6 TESTING <br /> ANNUAL TANK <br /> VADOZE <br /> ❑ 7 MON TORO INTERSTITIAL ❑ 8 SIR ❑ 9 TANEXGLY NGAL ❑10 TE NTTINGY TANKEja 95 UNKNOWN ❑99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PUCE) <br /> 1.ESTIMATED!=ED USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? YES ❑ NO❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DATE <br /> (PRINTED On <br /> 61ONATURE7 <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY tl q TANK M OO <br /> STATE I.D.# p p �v <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BYA PERMIT APPLICATION-FORMA,UNLESS A CURRENT FORMA HASBEENFILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS THISFORM <br /> SHOULD BE ACCOMPANIED BY A PLOT P FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE -RGROUND STORAGE TANK REGULATIONS <br /> FORMS (695) `/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.