My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
8750
>
2300 - Underground Storage Tank Program
>
PR0331843
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2021 10:35:13 PM
Creation date
11/4/2018 4:26:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0331843
PE
2381
FACILITY_ID
FA0003542
FACILITY_NAME
ALLIANCE
STREET_NUMBER
8750
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
FRENCH CAMP
Zip
95231
APN
19314001
CURRENT_STATUS
02
SITE_LOCATION
8750 S EL DORADO ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\8750\PR0331843\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
12/17/2012 8:00:00 AM
QuestysRecordID
79137
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL -')ARD <br /> FORM 'B': UNDEROROUND STORAGE TANK PROGRAM m� ^ <br /> TANK TANK PERMIT APPLICATION INFORMATION m b <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. _ <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION �❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM F-12 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE l!J o TANK REMOVED 07 <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: QFARM TANK-YES[0:1NO N <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: <br /> C.YEAR INSTALLED D. TANK CAPACITY IN GALLONS: 2S0 <br /> 11. TANK CONTENTS IF(A1),IS MARKED,COMPLETE ITEM C.IF(A1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL [—]2 ETROLEUM B. PRODUCT C ❑ UNLEADED ❑2 LEADED ❑3 DIESEL <br /> ❑3 CHEMICAL PRODUCE OIL ❑4 GASAHOL ❑5 JET FUEL E:] 6 AVIATION GAS <br /> E]5 HAZARDOUS [—] 80 EMPTY ❑95 UNKNOWN 2 WASTE ❑7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAMEOF ��77 <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# oil C.A.S.M /f.Q 3S <br /> III. TANK CONSTRUCTION MARKONE ITEM ONLY IN BOXAS,C,BD <br /> A. TYPE OF ❑ DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER F-1 95 UNKNOWN <br /> SYSTEM W9NGLEWALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> EV"'STEEUIRON ❑2 STAINLESS STEEL F-13 FIBERGLASS ❑4 STEEL==W/FIBERGLASS REINFORCED PIASTIC <br /> B. TANK ❑ <br /> MATERIAL 5 CONCRETE ❑6 POLYVINYLCHLORIDE F-17 ALUMINUM ❑8 IW%METHANOL COMPATIBLE FRP <br /> , <br /> ❑9 BRONZE ❑10 GALVANIZEDUM ❑95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR F-11 RUBBER UNED ❑2 ALKYD LINING E] 3 EPDXY LINING PHENOUC UNING <br /> LINING F-1S GLASS LINING ❑6 UNLINED 95 UNKNOWN <br /> ❑ IS UNING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D.CORROSION ❑ I POLYETHLENE WRAP ❑2 TAR OR ASPHALT QjVINYLWRAP F-14 FIBERGLASS REINFORCED PLASTIC <br /> El 5 CATHODIC PROTECTION ❑91 NONE 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMAT N CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION Afi- <br /> .�,SINGUE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLADW/FRP A U 810096 METHANOL COMPATIBLE ERP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 8 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> 1P S 6 PRECISION TESTING P 8 7 PRESSURE TESTING P 8 91 NONE P 8 95 UNKNOWN P 8 99 OTHER <br /> fi <br /> `41. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? E]YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> CURRENT LOCAL AGENCY FACILITY ID k APPROVED BY NAME PHONE M WITH AREA CODE <br /> Ilk,i-/A 9017 <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT PIRA ON DATE <br /> CHECK M PERMIT AMOUNT SURCHARGE ANT. FEE CODE RECEIPT N BY: <br /> FORM B(6-29-ee) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />