My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1000
>
2300 - Underground Storage Tank Program
>
PR0540264
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:22 AM
Creation date
11/4/2018 4:27:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0540264
PE
2381
FACILITY_ID
FA0009540
FACILITY_NAME
CALIF WELDING SUPPLY CO
STREET_NUMBER
1000
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
25016002
CURRENT_STATUS
02
SITE_LOCATION
1000 E ELEVENTH ST
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\1000\PR0540264\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
4/8/2013 8:00:00 AM
QuestysRecordID
82192
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNI w WATER RESOURCES CONTRC - BOARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM TANK TANK PERMIT APPLICATION INFORMATION (az <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEWPERMIT ❑3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK 10 <br /> ONE ITEM F--] 2 INTERIMPERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ®,8 TANK REMOVED <br /> N <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: " E, /e6" FARM TANK-YES❑ NO .A# <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY (� <br /> A. OWNERS TANK ID B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: 50 /dOO <br /> 11. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A_ S1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED DIESEL <br /> F-13 CHEMICAL PRODUCT ❑ 4 OIL 1 PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN !12 WASTE ❑7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN SOX A B,C,&D <br /> A.TYPE OF ❑ I DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR UNER AP5 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> F-11 STEEL/IRON ❑2 STAINLESS STEEL F-13 FIBERGLASS F-14 STEEL CUD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK <br /> MATERIAL F-15 CONCRETE ❑6 POLYWNYLGHLORIDE F-17 ALUMINUM ❑8100%METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL tg-%UNKNOWN ❑99 OTHER <br /> C. INTERIOR ❑ 1 RUBBER LINED ❑2 AU(YD LINING ❑3 EPDXY LINING ❑�.4�,PHENOUCUNING <br /> LINING F-1y <br /> 5 GLASSUNING ❑ 6 UNLINED 1�UNKNOWN e <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO 99 OTHER \l <br /> 0. CORROSION ❑I POLYETMENE WRAP ❑2TAR OR ASPHALT ❑�K3 VINYL WRAP F-14 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑9/ NONE Imo"UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A 5 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A CONCRETE A U ] STEEL CLAD W/FRP A U B 10096 METHANOL COMPATIBLE FqP <br /> A U 9 GALVANIZED STEEL U 5 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S I VISUAL CHECK P S 2 INVENTORY RECONCILIATION P 8 3 VADOOSE WELLS 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES <br /> GALLONS <br /> ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> E I UD2E Oaol <br /> CURRENT LOCAL AGENCY FACILITY ID k APPROVED BY NAME PHONE N WITH AREA CODE III k/N7 <br /> 1� <br /> PERMIT NUMBER PERMIT APPROVAL DATE PEAMITIEXPIRATION DATE <br /> ICHECK N PERMIT AMOUNT SURCHARGE AMT. FEE CODE P'CEIPT N BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM'A',UNLESS A CU ENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />