COMPLIANCE INFO 1998-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:31:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 1998-2004.PDF
QuestysFileName
COMPLIANCE INFO 1998-2004
QuestysRecordDate
5/19/2017 4:43:15 PM
QuestysRecordID
3389407
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> '97k1 0hWjYor Use By All Judsdicdons Within the State of Califft <br /> Authority Cited:Chapter 6lWalth and Safety Code;Chapter 16,Division 3 Title alifomia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must he prepared for each monitoring system°Omml panel Is orm to t eythe technician v4ho performs the laced agency regulating UST systems vn hinn 30 days of test date.rk. A copy of this form must be provided to the tank <br /> sys em ovmer operator. a ovmer operator must su mit a copy <br /> A.General Information City: TRACY CA Zip:95376 <br /> Facility Name: ULTRAMAR 698 <br /> Contact Phone NO:832-8815 <br /> Site Address: 153 E 11TH ST <br /> Date of Testing/Service: 03/20/2002 <br /> Facility Contact Person: MGR-CHEIA <br /> Make/Model of Monitoring System: GILBARCO EMC Work Order Number: 2221561 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: SUP Tank ID: REG 1 <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping SumplTrench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensm(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: EXTERNAL X Tank Overfill/High-Level Sensor. Model: EXTERNAL <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> an <br /> an <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Senores. Madel: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). <br /> Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> 71 Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Ispenser <br /> Dispenser Containment Sensors) Model: Dispenser Containment Sensor(s) Model: <br /> Shear Valve(s) <br /> Shear Valve(s). <br /> Dispenser Containment Floats)and Chain(s). <br /> Dispenser Containment Float(s)and Chain(s). <br /> Ispenser Ispenser <br /> Dispenser Containment Sensor(s) <br /> Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). <br /> Shear VaNe(s). <br /> Dispenser Containment Floats)and Chain(s). Dispenser Containment Floats)and Chain(s). <br /> Dispenser lD: DispenserlD: <br /> Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> QShear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> ' If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br /> a copy of the(Check all that apply): System set-up report; F� Alarm history report <br /> PRINTED NAME: <br /> MICHAEL T LEVESQUE SIGNATURE: <br /> COMPANY: Tanknology PHONE NO: (800)800-4633 <br /> page 1 of 3 Based on CA form dated 03/01 <br />