Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> Valero Corner Store#3698 February 8, 2011 <br /> Facility address: UST#I 4 5 6 <br /> 153 East 11 th Street, Tracy 95376 Product ' 87 a7 s1 <br /> Facility contact: Title: Phone: <br /> Sandy Huff/Jagtar Gill Compliant Crdr/ Mgr 559-583-3298 <br /> Monitoring panel: Piping system: Overfill prevention: Violations: <br /> Gilbarco EMC ❑XPressurized❑Suction❑Gravity ❑Mechanical❑X Audible/visual ❑M1-ROetect❑M2-RPrev❑M3-Both <br /> Inspection type: Designated operator: ICC exp.date: <br /> N Routine ❑X Monitoring Certification ❑Installation El other Donald W. Marcetti 08/13/12 <br /> On site Service Technician's name: ICC exp.date: JIIIAnyf�e s rai Ing: P- <br /> (G� w DEQ oa/ �� urjj�t (( � D g I� (I ab i'& <br /> # Code Section IOLATIONS R <br /> HSC=CA Health&SafetyCode;CCR=CA Code of Regulations;V=Violation RV=Re eat Violation V V <br /> 1 HSC 25284 No permit tooperate <br /> Secondary containment:(a)test not performed; (e)test report not submitted within 30 days; (0 test <br /> 2 CCR 2637 notificationnot provided to thronmental Health Department(EHD)at least 48 hours prior to <br /> conductin the test e EnviQ <br /> 3 CCR 2711 b Current Unified Program Consolidated Fortes not on file withthe EHD F cilit and tank form <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 CCR 2632(b) Monitoring Program(Monitodng&Response Plans is not current or approved by the EHD <br /> 6 CCR 2712(i) -Monitoring plan,response plan,and/or operating ermit and all conditions not onsite <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6 h (MI) <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling;(2)monitoring equipment calibration and maintenance records;(3)results <br /> of any visual observations;(4)results of sample analysis performed a lab or in the field;(5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations, or other test results;(6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643d Daily monitoring of suction piping(pre-January1 1984 not performed M7 <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitials ace of a double walled UST 147 <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(mi) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (Mt) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (Mt) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 1 CCR 2636(c)(1) All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636(0(2) Line leak detectors not installed or failed to detect a 3-gallon per hour leak at 10 psi Mt <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means (M2) <br /> to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (Mz) <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) Mz <br /> 21 HSC 25291 a Water in 2°containment not removed,analyzed&properly disposed of <br /> Unauthorized release that: (c)did not escape secondary containment and cleaned up within eight (M7) <br /> 22 CCR 2650 hours was not recorded; (e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23aCR C2715 a Failed to inform the EHD of a change of designated operator within 30 days <br /> 236 CCR 2715 b Designated operator did not possess a current ICC UST S stem O erator certification <br /> EHD inspector: Received by: Tifle: <br /> EHD 23-02-002 REV 0811 Page 1 UST INSPECTION REPORT <br />