Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209) 468-3433 Web:www.siaov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Valero Corner Store#3698 1 153 E ELEVENTH ST, TRACY nuary 28, 2015 <br /> UST System Observations <br /> 322 CCR 2636(f)(2) Line leak detector not installed ❑V o R n COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ❑V ❑R ❑COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty o V ❑R o COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons o V o R o COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present,was overridden,or failed to meet overfill requirements ❑V ❑R ❑COS <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status in V in R in COS <br /> 328 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 329 CCR 2717.1(f i Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 330 HSC 25299(%2) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements I ❑V o R a COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V ❑R o COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation n V o R n COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation o V o R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br /> The 91 and 87-master annular sensors were sifting in the dirt, not in the interstitial space upon arrival. The <br /> interstitial space shall be monitored with a monitoring system connected to an audible and visual alarm system. <br /> According to the alarm history there had not been any alarms since the last monitoring certification 2/2014. <br /> Secondary containment testing of the system was perfromed July 2014. No other maintenance documents were <br /> seen. The technician onsite tested the sensors during the monitoring certification. Both activated the audible and <br /> visual alarms. After testing the sensors were placed back into their proper location. <br /> Take all necessary precautions in the future to ensure the interstitial space is monitored. <br /> Corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Ce ' cation form to the EHD with a statement <br /> Received by(initisInspector: one: Date: <br /> MICHELLE HENRY, Senior REHS (209) 468-3454 01/28/2015 <br /> Page 3 4 <br />