My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:35:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2012-2015.PDF
QuestysFileName
COMPLIANCE INFO 2012-2015
QuestysRecordDate
5/19/2017 9:21:29 PM
QuestysRecordID
3390491
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swreb.ra.gov.) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: VALERO 3698 Bldg. No.: <br /> Site Address: 153 E 11TH STQC-D-3 City: TRACY Zip: 95376 <br /> Facility Contact Person: MGR-CHELA Contact Phone No.: 832-8815 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 2/6/2013 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment ins ected serWced: <br /> Tank ID: T3-UNLEADED Tank ID: T2-UNLEADED <br /> V, In-Tank Gauging Probe. Madel: mag r In-Tank Gauging Probe. Madel: mag <br /> Annular Space or Vault Sensor. Model: 420 r Annular Space or Vault Sensor. Model: 420 <br /> FF. Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: 208 <br /> r Fill Sump Sensor(s). Model: 208 r Fill Sump Sensor(s). Model: 208 <br /> r Mechanical Line Leak Detector. Model: Red Jacket FXSV r Mechanical Une Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: ( Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor.Model: external alarm r Tank Overfill/Hlgh-Level Sensor.Model: external alar <br /> Other(specify equipment a and model in Section E on Pa e 2. Other(specify equipment and model in Section E on Pace 2). <br /> Tank ID: T3-PREMIUM Tank ID: <br /> r_ In-Tank Gauging Probe. Model: mag r In-Tank Gauging Probe. Model: <br /> r Annular Space or Vault Sensor. Model: 420 Annular Space or Vault Sensor. Model: <br /> r Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: <br /> r Fill Sump Sensor(s). Model: 208 [ Fill Sump Sensor(s). Model: <br /> r Mechanical Line Leak Detector. Model: Red Jacket FXIV r Mechanical Line Leak Detector. Model: <br /> IF Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: external alar r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment and model in Section E on Pae 2. Others ci a ui ment type and model In Section E on Pae 2), <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> r Shear Valve(s). r Shear Valve(s). <br /> W,Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> r Shear Valve(s). r Shear Valve(s). <br /> We,Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chaln(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> r Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Floats)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified In this document was inspected/serviced In accordance with the manufacturers'guidelines.Attached to <br /> this Certification is Information(e.g.manufacturers'checklists)necessary to verify that this Information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):r System set- <br /> up r.Alarm history report <br /> Technician Name(print): Jarrod Cooke Signature: <br /> Certification No.: B35255 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)8004633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 2/6/2013 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.