Laserfiche WebLink
IFIED PROGRAM CONSOLIDATED F <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION One form <br /> TYPE NEW <br /> ACTION (Check one item only, For an UST permanent closure or removal,complete only this section and Sections I,it,III,N,and IX beloper w) at0 <br /> ❑ 1.NEW PERMIT ® 3.RENEWAL PERMIT <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 5.CHANGE OF INFORMATION <br /> DATE UST PERMANENTLY CLOSED: 430a ❑ 8.UST REMOVAL <br /> DATE EXISTING UST DISCOVERED: 430n <br /> FACILITY ID#(Agency Use Only) L FACILITY INFORMATION <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 4 `� 4 3 <br /> Valero Corner Store#3698 <br /> BUSINESS SITE ADDRESS <br /> 153 E.1 I ni Street 103 CITY <br /> Tracy 04 <br /> TANK ID# 3698-2II.TANK DESCRIPTION <br /> 432 TANK MANUFACTURER 433 <br /> TANK CONFIGURATION: <br /> Modern Welding THIS TANK IS <br /> I.A STAND-ALONE TANK 434 <br /> DATE UST SYSTEM INSTALLED 415 ❑2.ONE M A COMPARTMENTED UNIT. <br /> TANKCAPACITY W GALLONS 436 Com fete one eron each cc anment in the unit. <br /> 10/01/1987 10000 NUMBER OF COMPARTMENTS IN THE UNIT 432 <br /> TANK USEUELING III.TANK.USE AND CONTENTS <br /> ® la.MOTOR VEHICLE FUELING ❑ Ib.MARINA F <br /> ❑ 3.CHEMICAL PRODUCT STORAGE [3 4.HAZARDOUSWASTE(Includes 13 Ic.AVIATION FUELING 439 <br /> FUEL Used Oil? <br /> ❑ 6.OTHER GENERATOR ❑ 5.EMERGENCY GENERATOR <br /> FUEL[HSC§25281.5(c)j <br /> ® la <br /> CONTENTS PETROLEUM: ❑ 95.DNKNOWN ❑ 99.OTHER (Specify).REGULAR UNLEADED ❑ Ic.MIDGRADE UNLEADED ( ce 439a <br /> [1 3.DIESEL ❑ 5.JET FUEL in PREMIUM UNLEADED 440 <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9,OTFBiR THANOL PETROLEUM � 6.AVIATION GAS <br /> NON-PETROLEUM:' 7.USED OIL (S ci ): awa <br /> ❑ I1.OTHER NON-PETROLEUM(S ❑ 10.Eecif): <br /> IV. TANK CONSTRUCTION 44on <br /> PRIMAR CON ❑ L SINGLE WALL <br /> PRiMARy CONTAINMENT ® 2.DOUBLE WALL ❑ 95.UNKNOWN <br /> ® 1.STEEL ❑ 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 443 <br /> SECONDARYCONTAINMENT 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN 444 <br /> ❑ 1.STEEL ❑3.FBERGLASS ❑ 99.OTHER (S if); 4a4a <br /> ❑ 90.NONE ❑ 95.UNKNOWN 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED <br /> OVERFILL PREVENTION ®99.OTHER(S cif): FRP coated steel 445 <br /> ® 1.AUDIBLE&VISUAL ALARMS ❑ 2,BALL FLOAT 445a <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQI USE UIPMENT <br /> PIPING <br /> 452' <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTR UC TION ❑ I.SINGLE-WALLED ®2,DOUBLG-WALLED <br /> SYSTEM TYPE ® I.PRESSURE ❑99.OTHER <br /> PRIMARY CONTAINMENT ❑ 2 GRAVITY ❑ 3.CONVENTIONAL SUCTION 460 <br /> ❑ 1.STEEL 29 4,FIBERGLASS ❑ 8.FLEXIBLE 4,SAFE SUCTION 123 CCR§2636(a)(3p 458 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.GTHER(S cif): l0.RIGID PLASTIC 464 <br /> SECONDARY CONTAINMENT ❑ 1.$TEFL 44 <br /> ® 4.FIBERGLASS ❑ g,FLEXIBLE ❑ 10.RIGID PLASTIC <br /> Ma <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 4641, <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE 461, <br /> ® I.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE <br /> VI. VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ LSTEEL <br /> ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464c <br /> VENT SECONDARY CONTAINMENT ❑ LSTEEL ❑ 4.FIBERGLASS <br /> ❑ 10.RIGID PLASTIC ® 90.NONE 4644 <br /> VR PRIMARY CONTAINMENT ❑ 99.OTHER(Specify) 4644 <br /> ) 4 <br /> ❑ I.STEEL R9 4,FIBERGLASS ❑ 10.RIGID PLASTIC ❑ W.NONE ❑ 99.OTHER(Specify) 464171 <br /> 464 <br /> VR SECONDARY CONTAINMENT ❑ 1.STEEL s <br /> ❑ 4.FIBERGLASS ❑ 10,RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify) 44641 <br /> VENT PIPING TRANSITION SUMP TYPE ❑ LSM:L WALL M,411 <br /> RISER PRIMARY CONTAINMENT ® 1.STEEL ❑ 2.DOUBLE WALL ® 90.NONE 4641 <br /> ❑ 4.FIBERGLASS ❑ 10.RIGm PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4641 <br /> RISER SECONDARY CONTAINMENT ❑ I.STEEL ® 4.FIBERGLASS g641 <br /> ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 41 <br /> FILL COMPONENTS INSTALLED ® 1.SPILL BUCKET ® 3,STRIKER PLATE/BOTTOM PROTECTOR ® 4.CONTAINMENT SUMP JAukc <br /> CONSTRUCTIONMTYPE <br /> A"fER1AI, VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONS T"RUCTION ® 1.SINGLE WALL ❑ 2. ^E <br /> DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE'' <br /> 469a <br /> ® L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(S cif) 4691,-c <br /> VIII. CORROSION PROTECTION <br /> STGBL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) <br /> ❑ 4.IMPRESSED CURRENT ® 6.ISOLATION 448. <br /> LICANT <br /> CERTIFICATION: Ice [ha[this UST system is comps[IX. <br /> le wi[hPthe ha douse substancestored and that the information provided herein-is[rue,accurate, <br /> and in full com Bance with le al re uiremen[s. <br /> APPLICANT SIGNATURE DATE <br /> I a 7 470. <br /> APPLICANT NAME(print) Sandy Huff 471. <br /> APPLICANT TITLE Compliance Coordinator 472. <br /> UPCF UST-B-1/1 <br /> Rev.(12/2007) <br />