My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
11
>
2300 - Underground Storage Tank Program
>
PR0516324
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 2:17:21 PM
Creation date
11/4/2018 4:52:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0516324
PE
2381
FACILITY_ID
FA0012558
FACILITY_NAME
LODI, CITY OF
STREET_NUMBER
11
Direction
W
STREET_NAME
ELM
STREET_TYPE
ST
City
LODI
Zip
952411910
CURRENT_STATUS
02
SITE_LOCATION
11 W ELM ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELM\11\PR0516324\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
4/2/2013 8:00:00 AM
QuestysRecordID
87246
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/IFIBD PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> _ a <br /> YI, VI.PIPING CONSTRUCTION(Chock d OW apply) P"o <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ❑ 1. PRESSURE 2. SUCTION E3 3. GRAVITY 450 [31. PRESSURE C] 2. SUCTION ❑ 7. GRAVITY 459 <br /> CONSTRUCTIONX I• SINGLE WALL ❑ 0. LINED TRENCH E3 m. OTHER 480 ❑ 1. SINGLE WALL ❑95. UNKNOWN 462 <br /> MANUFACTURER❑ 2 DOUBLE WALL ❑95. UNKNOWN ❑ 2. DOUBLE WALL ❑99. OTHER <br /> MANUFACTURER 461 MANUFACTURER 467 <br /> 1.BARE STEEL ❑ 0. FRP COMPATIBLE W/IW%METHANOL ❑ 1. BARE STEEL ❑ S. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL ❑ 2 STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br /> CORROSION ❑ 7 PLASTIC COMPATIBLE WITH CONTENTS ❑95. UNKNOWN ❑ S. PLASTIC COMPATIBLE WITH CONTENTS ❑ S. FLEXIBLE(HOPE) ❑99. OTHER <br /> PROTECTION <br /> ❑ 4. FIBERGLASS ❑ S. FLEXIBLE(HOPE) ❑99. OTHER ❑ 4. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br /> _ ❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION 464 ❑ 5. STEEL W/COATING ❑95. UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION(UaaYaEMwrppy) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 4a0 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Char,as fMf appy): PRESSURIZED PIPING(ChaptrW f t appy): <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 7.0 GPH TEST WITH AUTO RUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 7.0 GP11 TEST WITH AUTO Pump SHUT OFF FOR LEAs( <br /> LEAK SYSTEM FAILURE AND SYSTEM DISCONNECTION+AUDELLE AND VISUAL SYSTEM FAILURE.AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS ❑ 2 MONTHLY 01 GPH TEST <br /> ❑ 2 MONTHLY 02 GPM TEST ❑ S. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 7. ANNUAL INTEGRITY TEST(ILI GPH) 1f, I <br /> -` IjU1t\(\', ❑ .. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Ger,as That apply): <br /> ❑ S DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENINIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) ❑ S. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑ 7. SLIFMONrTORING ❑ 7. SELF MONITORING <br /> SRAVfTY FLOW: GRAVITY FLOW(Ch.X*Y N.f appy): I <br /> 9. BIENNIAL INTEGRITY TEST(0.1 GPH) ❑ S. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> 'RESSURIZED PIPING(CINdr Y Nat appy): PRESSURIZED PIPING(Ger,ae fhaf appy): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(dl.& <br /> (Cher,ana) oro) <br /> ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ 0. AUTO PUMP SHUT OFF FOR LEAKS.SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION ❑ E. AUTO PUMP SHUT OFF FOR LEAKS SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> ❑ c NO AUTO PUMP SHUT OFF ❑ C. NO AUTO PUMP SHUT OFF <br /> ] 11. AUTOMATIC LINE LEAK DETECTOR(7.0 GPH TEST)WITH FLOW SHUT OFF OR <br /> RESTRICTION ❑ 11. AUTOMATIC LEAK DETECTOR <br /> ] 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> IUCTIOWGRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: <br /> ] 17. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> ❑ 17. CONTINUOUS SUMP SENSOR•AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Lack Y 0W appy) <br /> ] 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND EMERGENCY GENERATORS ONLY(Gad ad that appy) <br /> VISUAL ALARMS ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF.AUDIBLE AND VISUAL <br /> ] 15. AUTOMATIC LINE LEAK DETECTOR(7.0 GPH TEST)WWM40UTT FLOW SHUT OFF OR ALARMS <br /> RESTRICTION C315. AUTOMATIC LINE LEAK DETECTOR(0.0 GPH TEST) <br /> ] 16. ANNUAL INTEGRITY TEST(o.1 GPH) ❑ 10. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 17. DAILYVISUALCHECK ❑ 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> ISPENSER CONTAINMENT ❑ 1. FLOAT MEOHAmrm THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br /> DATE INSTALLED 468 ❑ 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ S. TRENCH LINER MONITORING <br /> ❑ S. CONTINUOUS DISPENSER PAN SENSOR�!M AUTO SHUTOFF FOR DISPENSER AUDIBLE NO VISUAL ALARMS ❑ S. NONE 4" <br /> st;.. OL OWNER)OPERATOR:SIGNATURE <br /> c," <br /> Infq llc n prwd "n Is Yue anp a 10 W.I.0.tl of my kraMedpa. <br /> SIGlU r �f�:TO DATE 470 <br /> D <br /> VAME OF OWNERIOPERATOR ) 471 T Tp <br /> OF OWN RrOPE R� " 472 <br /> T M u+ 1 i� rur� OWE - <br /> 'amM NumOar(For bW use a*) 477 I Parml Appy (F«b al tea.m7'1 474 Pamv1 EaWfa6an DM.rF«bW ua.«YYI 475 <br /> 'CF(1/99) Formerty SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.