My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
230
>
2300 - Underground Storage Tank Program
>
PR0231330
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2021 11:24:16 PM
Creation date
11/4/2018 4:53:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231330
PE
2361
FACILITY_ID
FA0003964
FACILITY_NAME
LODI PUBLIC SAFETY BUILDING
STREET_NUMBER
230
Direction
W
STREET_NAME
ELM
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04303109
CURRENT_STATUS
02
SITE_LOCATION
230 W ELM ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELM\230\PR0231330\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
4/3/2013 8:00:00 AM
QuestysRecordID
87072
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNI WATER RESOURCESCONTR( BOARD <br /> FORM 'B': UNDMGROUND STORAGE TANK PRO-GRAM W' <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. ^" Z <br /> e.o <br /> 10 f <br /> MARK ONLY ❑ 1 NEW PERMIT [-13 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑77PPERMANENTLY CLOSED TANK <br /> ONE ITEM F--] 2 INTERIM PERMIT F-14 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE P TANK REMOVED O q <br /> N <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: FARM TANK-YES❑ NO A <br /> LC <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY N <br /> A, OWNERS TANK ID# - B. MANUFACTURED BY: <br /> C.YEAR INSTALLED D. TANK CAPACITY IN GALLONS: Lgoolo <br /> H. TANK 52NTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> 14 - <br /> A. 1 MOTOR VEHICLE FUEL E] 2 PETROLEUM B. C. ❑ 1 UNLEADED El LEADED DIESEL <br /> E�K <br /> IL <br /> GAS <br /> ❑ 5 HAZARDOUS ODUCT OEMPTY 95 UNKNOWN ❑2 WAOSTTECT ❑7 METHANOL �O7HER(DESCRIBE❑IN TEM D?BELL <br /> 80 [-] OW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF I <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.# F&c e / 0 i -- O/e-3e- D.A.S.#: b <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM Yaltil`NGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> 1 STEEUIRGN ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CUD W/RBERGLASS REINFORCED PLASTIC <br /> B TANK <br /> MATERIAL ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ B 1DD%METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR ❑ 1 RUBBER LINED ❑2 AU(YD UNING ❑ 3 EPDXY UNING ❑4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS UNING ❑6 UNLINED UNKNOWN <br /> ❑IS UNING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ 1 POLYEfHLENEWPAP ❑2 TAR OR ASPHALT ❑3 VNft WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PflOTECTiON ❑5 CATHODIC PROTECTION ❑91 NONE 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE AOnUNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U B /00%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZEDSTEEL A 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 5 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 3 3 VADOSE WELLS P S d ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P 5 6 PPECISION TESTING P S 7 PRESSURE TESTING P 91 NONE P S 95 UNKNOWN P 6 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING INGALLONS INERT MATERIAL? ❑YES [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> EH = O b l 3 3 O <br /> CURRENT LOCALLv AOENC FACT TTY IO a# APPROVED BY ME PHONE#WITH AREA CODE <br /> r' � 3 <br /> PERMIT NUMBER PERMIT APPROVAL DAT PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT I SURCHARGEAMT. FEE CODE RECEIPT# BY: <br /> FORM B S-29-99) THIS FORM MUST BE ACCOMPANIEL,III A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> 'TATA PROCESSING COPY <br />