My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
7717
>
2300 - Underground Storage Tank Program
>
PR0231870
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2020 10:41:46 AM
Creation date
11/4/2018 4:55:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231870
PE
2361
FACILITY_ID
FA0003953
FACILITY_NAME
AT&T California - UE148
STREET_NUMBER
7717
STREET_NAME
ELM
STREET_TYPE
St
City
French Camp
Zip
95231
CURRENT_STATUS
02
SITE_LOCATION
7717 Elm St
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELM\7717\PR0231870\BILLING 1986-2003.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root California Edition:June 2001 <br /> TLS-250, 250i, 300, 300C, 300i, 300PC, 350, 350PC, 350R, 350RPC UST ATGS <br /> (Models 8473, 8493 Magnetostrictive Probes) <br /> AUTOMATIC TANK GAUGING METHOD <br /> Certification: Leak rate of 0.2 gph with Po=98.9%and PFA=0.3%. <br /> Leak rate of 0.1 gph with Po=95.8%and PFA=0.9%. <br /> Leak Threshold: 0.126 gph for leak rate of 0.2 gph. <br /> 0.071 gph for leak rate of 0.1 gph. <br /> A tank system should not be declared tight if the test result indicates a loss or gain that equals or <br /> exceeds this threshold. <br /> Applicability: Gasoline,diesel,aviation fuel. <br /> Other liquids with known coefficients of expansion and density may be tested after consultation with <br /> the manufacturer. <br /> Tank Capacity: Maximum of 15,000 gallons. <br /> Tanks less than 95%full may be tested. <br /> Minimum product level required is based on tank diameter as follows: <br /> 48"dial min 18";64"dial min 21"; 72"dial min 24";96"dial min 30"; 126"dial min 39". <br /> For other tank diameters,see evaluation report. <br /> Waiting Time: Minimum of 8 hours between delivery and testing. <br /> Minimum of 30 minutes between dispensing and testing. <br /> There must be no delivery during waiting time. <br /> Test Period: Minimum of 2 hours for leak rate of 0.2 gph. <br /> Minimum of 3 hours for leak rate of 0.1 gph. <br /> Test data are acquired and recorded by the system's computer. <br /> Leak rate is calculated from the difference between the first and last data collected. <br /> There must be no dispensing or delivery during test. <br /> Temperature: Average for product is determined by probe which contains 5 thermistors.At least one thermistor <br /> must be submerged in product during test. <br /> Water Sensor: Must be used to detect water ingress. <br /> Minimum detectable water level in the tank is 0.544 inch. <br /> System is programmed to report water depth only when it exceeds 0.75 inch. <br /> Minimum detectable change in water level is 0.027 inch. <br /> Calibration: Thermistors and probe must be checked and,if necessary;calibrated in accordance with <br /> manufacturers instructions. <br /> Comments: Not evaluated using manifolded tank systems. <br /> Tests only portion of tank containing product. <br /> As product level is lowered,leak rate in a leaking tank decreases(due to lower head pressure). <br /> Consistent testing at low levels could allow a leak to remain undetected. <br /> EPA regulations require testing of the portion of the tank which routinely contains product. <br /> California regulations require at least one test per month after routine product delivery or <br /> when the tank is filled to within 10%of the highest operating level of the previous month. <br /> If the 0.1 gph test is used as a tank tightness test there must be no water present in the <br /> backfill(groundwater must be below the bottom of the tank),the tank must be equipped with <br /> an overfill protection device,and the product level in the tank must be at the overfill protection <br /> device set point.Local agency pre-approval is required.To use this as a monthly test option <br /> see title 23 CCC Section 2643(b)(2). <br /> Veeder-Root Evaluator. Midwest Research Institute <br /> 125 Powder Forest Dr. Tel: (816) 753-7600 <br /> Simsbury, CT 06070-7684 Date of Evaluation: 09/04/97, 07/01/98 <br /> Tel: (860) 651-2700 <br /> 257 <br /> Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the <br /> performance of the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and <br /> regulations. <br />